Determination of SCH 211803 by nanoelectrospray infusion mass spectrometry: evaluation of matrix effect and comparison with liquid chromatography-tandem mass spectrometry

被引:12
作者
Chen, JW
Yang, LY
Kapron, JT
Ma, L
Pace, E
Van Pelt, CK
Rudewicz, PJ
机构
[1] Schering Plough Res Inst, Kenilworth, NJ 07033 USA
[2] Advion Biosci, Ithaca, NY 14850 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 809卷 / 02期
关键词
matrix effects; nanoelectrospray infusion; SCH; 211803;
D O I
10.1016/j.jchromb.2004.06.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high throughput assay for SCH 211803, an M2 muscarinic receptor antagonist in human plasma using nanoelectrospray infusion tandem mass spectrometry is described. Sample processing consisted of protein precipitation followed by solid phase extraction using octadecasilyl resin-filled pipette tips on a liquid handling robotic system. The sample extracts were infused directly to the mass spectrometer using a nanoelectrospray interface in a silicon chip format. SCH 211803 was quantified in plasma over the concentration range of 1-1000 ng/mL. In comparison with a liquid chromatography-tandem mass spectrometry assay, the nanoelectrospray method has comparable accuracy, precision and limit of quantitation, with a nine-fold improvement in sample throughput. Using the nanoelectrospray assay, ion suppression was evaluated and found to be 15%. This represented a four-fold reduction in matrix suppression when compared to a conventional electrospray source operating in the flow injection analysis mode at a flow rate common for LC-MS/MS analysis. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 16 条
[1]   Derivatization of ethinylestradiol with dansyl chloride to enhance electrospray ionization: Application in trace analysis of ethinylestradiol in rhesus monkey plasma [J].
Anari, MR ;
Bakhtiar, R ;
Zhu, B ;
Huskey, S ;
Franklin, RB ;
Evans, DC .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4136-4144
[2]   Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[3]  
Cheng YF, 2001, RAPID COMMUN MASS SP, V15, P141, DOI 10.1002/1097-0231(20010130)15:2<141::AID-RCM201>3.0.CO
[4]  
2-I
[5]   Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry [J].
Dethy, JM ;
Ackermann, BL ;
Delatour, C ;
Henion, JD ;
Schultz, GA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :805-811
[6]   Reduction of signal suppression effects in ESI-MS using a nanosplitting device [J].
Gangl, ET ;
Annan, M ;
Spooner, N ;
Vouros, P .
ANALYTICAL CHEMISTRY, 2001, 73 (23) :5635-5644
[7]   Analysis of a tryptic digest of pig hemoglobin using ESI-FAIMS-MS [J].
Guevremont, R ;
Barnett, DA ;
Purves, RW ;
Vandermey, J .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4577-4584
[8]   Quantitation of midazolam in human plasma by automated chip-based infusion nanoelectrospray tandem mass spectrometry [J].
Kapron, JT ;
Pace, E ;
Van Pelt, CK ;
Henion, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (18) :2019-2026
[9]   Mechanistic investigation of ionization suppression in electrospray ionization [J].
King, R ;
Bonfiglio, R ;
Fernandez-Metzler, C ;
Miller-Stein, C ;
Olah, T .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (11) :942-950
[10]   Description and validation of a staggered parallel high performance liquid chromatography system for good laboratory practice level quantitative analysis by liquid chromatography/tandem mass spectrometry [J].
King, RC ;
Miller-Stein, C ;
Magiera, DJ ;
Brann, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (01) :43-52