Proteome-on-a-chip: Mirage, or on the horizon?

被引:93
作者
Freire, Sergio L. S.
Wheeler, Aaron R.
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
[2] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 3G9, Canada
[3] Univ Toronto, Banting & Best Dept Med Res, Toronto, ON M5G 1L6, Canada
关键词
D O I
10.1039/b609871a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Proteomics has emerged as the next great scientific challenge in the post- genome era. But even the most basic form of proteomics, proteome profiling, i. e., identifying all of the proteins expressed in a given sample, has proven to be a demanding task. The proteome presents unique analytical challenges, including significant molecular diversity, an extremely wide concentration range, and a tendency to adsorb to solid surfaces. Microfluidics has been touted as being a useful tool for developing new methods to solve complex analytical challenges, and, as such, seems a natural fit for application to proteome profiling. In this review, we summarize the recent progress in the field of microfluidics in four key areas related to this application: chemical processing, sample preconcentration and cleanup, chemical separations, and interfaces with mass spectrometry. We identify the bright spots and challenges for the marriage of microfluidics and proteomics, and speculate on the outlook for progress.
引用
收藏
页码:1415 / 1423
页数:9
相关论文
共 101 条
[1]  
Appella E, 2000, EXS, V88, P1
[2]   A MALDI-chip integrated system with a monitoring window [J].
Brivio, M ;
Tas, NR ;
Goedbloed, MH ;
Gardeniers, HJGE ;
Verboom, W ;
van den Berg, A ;
Reinhoudt, DN .
LAB ON A CHIP, 2005, 5 (04) :378-381
[3]   Integrated microfluidic system enabling (bio)chemical reactions with on-line MALDI-TOF mass spectrometry [J].
Brivio, M ;
Fokkens, RH ;
Verboom, W ;
Reinhoudt, DN ;
Tas, NR ;
Goedbloed, M ;
van den Berg, A .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :3972-3976
[4]   Microfabricated polymer devices for automated sample delivery of peptides for analysis by electrospray ionization tandem mass spectrometry [J].
Chan, JH ;
Timperman, AT ;
Qin, D ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4437-4444
[5]  
Chen SH, 2001, ELECTROPHORESIS, V22, P3972, DOI 10.1002/1522-2683(200110)22:18<3972::AID-ELPS3972>3.0.CO
[6]  
2-6
[7]   A prototype two-dimensional capillary electrophoresis system fabricated in poly(dimethylsiloxane) [J].
Chen, XX ;
Wu, HK ;
Mao, CD ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1772-1778
[8]   Membrane-based nanoscale proteolytic reactor enabling protein digestion, peptide separation, and protein identification using mass spectrometry [J].
Cooper, JW ;
Chen, JZ ;
Li, Y ;
Lee, CS .
ANALYTICAL CHEMISTRY, 2003, 75 (05) :1067-1074
[9]   Poly(dimethylsiloxane)-based microchip for two-dimensional solid-phase extraction-capillary electrophoresis with an integrated electrospray emitter tip [J].
Dahlin, AP ;
Bergström, SK ;
Andrén, PE ;
Markides, KE ;
Bergquist, J .
ANALYTICAL CHEMISTRY, 2005, 77 (16) :5356-5363
[10]   Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip [J].
Dahlin, AP ;
Wetterhall, M ;
Liljegren, G ;
Bergström, SK ;
Andrén, P ;
Nyholm, L ;
Markides, KE ;
Bergquist, J .
ANALYST, 2005, 130 (02) :193-199