Transapical transcatheter aortic valve implantation

被引:11
作者
Beyersdorf, Friedhelm [1 ]
机构
[1] Univ Freiburg, Dept Cardiovasc Surg, Freiburg, Germany
关键词
STENT IMPLANTATION; CLOSURE; PERFORATION; EXPERIENCE; OCCLUDER; DEVICE; HUMANS;
D O I
10.1016/j.ejcts.2006.11.003
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
引用
收藏
页码:7 / 8
页数:2
相关论文
共 14 条
[1]
TRANSLUMINAL IMPLANTATION OF ARTIFICIAL-HEART VALVES - DESCRIPTION OF A NEW EXPANDABLE AORTIC-VALVE AND INITIAL RESULTS WITH IMPLANTATION BY CATHETER TECHNIQUE IN CLOSED CHEST PIGS [J].
ANDERSEN, HR ;
KNUDSEN, LL ;
HASENKAM, JM .
EUROPEAN HEART JOURNAL, 1992, 13 (05) :704-708
[2]
Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[3]
Transapical transcatheter aortic valve implantation in humans - Initial clinical experience [J].
Lichtenstein, Samuel V. ;
Cheung, Anson ;
Ye, Jian ;
Thompson, Christopher R. ;
Carere, Ronald G. ;
Pasupati, Sanjeevan ;
Webb, John G. .
CIRCULATION, 2006, 114 (06) :591-596
[4]
Closed heart surgery: Back to the future [J].
Lichtenstein, SV .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05) :941-943
[5]
BALLOON AORTIC VALVULOPLASTY IN ADULTS - FAILURE OF PROCEDURE TO IMPROVE LONG-TERM SURVIVAL [J].
LIEBERMAN, EB ;
BASHORE, TM ;
HERMILLER, JB ;
WILSON, JS ;
PIEPER, KS ;
KEELER, GP ;
PIERCE, CH ;
KISSLO, KB ;
HARRISON, JK ;
DAVIDSON, CJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (06) :1522-1528
[6]
Percutaneous aortic valve replacement: An experimental study. I. Studies on implantation [J].
Lutter, G ;
Kuklinski, D ;
Berg, G ;
von Samson, P ;
Martin, J ;
Handke, M ;
Uhrmeister, P ;
Beyersdorf, F .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (04) :768-776
[7]
DEVELOPMENT AND INITIAL EXPERIMENTAL EVALUATION OF A PROSTHETIC AORTIC-VALVE FOR TRANSCATHETER PLACEMENT - WORK IN PROGRESS [J].
PAVCNIK, D ;
WRIGHT, KC ;
WALLACE, S .
RADIOLOGY, 1992, 183 (01) :151-154
[8]
Closure of left ventricle perforation with the use of muscular VSD occluder [J].
Pawelec-Wojtalik, M ;
von Segesser, LK ;
Liang, M ;
Bukowska, D .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (04) :714-716
[9]
Use of muscular VSD amplatzer occluder for closing right ventricular free wall perforation after hybrid procedure [J].
Pawelec-Wojtalik, M ;
Antosik, P ;
Wasiatycz, G ;
Wojtalik, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (05) :1044-1046
[10]
Is device closure for direct access valved stent implantation safe? [J].
Pawelec-Wojtalik, Malgorzata ;
Nozynski, Jerzy ;
Wojtalik, Michal ;
Piaszczynski, Maciej ;
Surmacz, Rafal ;
Bukowska, Dorota ;
Mrowczynski, Wojciech .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (01) :4-9