Internal loads in the human tibia during gait

被引:109
作者
Wehner, Tim [1 ]
Claes, Lutz [1 ]
Simon, Ulrich [1 ,2 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech, D-89069 Ulm, Germany
[2] Univ Ulm, Ulm Ctr Sci Comp, D-89069 Ulm, Germany
关键词
Inverse dynamics; Musculoskeletal load; Internal load; Internal force; Human; Tibia; IN-VIVO; CONTACT FORCES; MUSCLE FORCES; LOWER-LIMB; HIP; WALKING; FEMUR; MODEL; ARTHROPLASTY; COMPRESSION;
D O I
10.1016/j.clinbiomech.2008.12.007
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Background: Internal loads in long bones are of special interest, for testing and optimization of current implant designs for fracture treatment. Inverse dynamic musculoskeletal models were successfully used to determine the muscle forces in the lower extremities, however the internal loads expressed as forces and moments along the human tibia during gait have not been reported. Methods: A musculoskeletal model of the lower extremities, developed and provided under public domain from the AnyBody research group (www.anybody.aau.dk), was modified to determine the three-dimensional internal loads along the tibial axis during gait. To corroborate this numerical model, the calculated resultant hip contact force as well as the axial force on the tibial plateau were compared to in vivo data from the literature. Findings: The highest internal loads were the axial force with up to 4.7 bodyweight and the bending moment in the sagittal plane with up to 71.6 bodyweight times millimetre in the late stance phase. The extreme values of the internal loads along the tibial axis varied up to 1.5 bodyweight and 85.7 bodyweight times millimetre. In the distal part of the tibia, the axial force dominated the three-dimensional internal load case, whereas the internal moments became more significant with increasing distance from the ankle joint. Interpretation: This study provides for the first time the three-dimensional internal loads, expressed as forces and moments along the human tibia during normal gait. The results of this study could be used to improve the mechanical behaviour of current implant designs for the treatment of tibial fractures to avoid implant failures under in vivo loading conditions. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:299 / 302
页数:4
相关论文
共 29 条
[1]
Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? [J].
Ahmad, M. ;
Nanda, R. ;
Bajwa, A. S. ;
Candal-Couto, J. ;
Green, S. ;
Hui, A. C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (03) :358-364
[2]
HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[3]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[4]
Brand R A, 1994, J Arthroplasty, V9, P45, DOI 10.1016/0883-5403(94)90136-8
[5]
THE SENSITIVITY OF MUSCLE FORCE PREDICTIONS TO CHANGES IN PHYSIOLOGICAL CROSS-SECTIONAL AREA [J].
BRAND, RA ;
PEDERSEN, DR ;
FRIEDERICH, JA .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :589-596
[6]
The Chitranjan Ranawat Award - In vivo knee forces after total knee arthroplasty [J].
D'Lima, DD ;
Patil, S ;
Steklov, N ;
Slamin, JE ;
Colwell, CW .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :45-49
[7]
TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[8]
Influence of muscle forces on femoral strain distribution [J].
Duda, GN ;
Heller, M ;
Albinger, J ;
Schulz, O ;
Schneider, E ;
Claes, L .
JOURNAL OF BIOMECHANICS, 1998, 31 (09) :841-846
[9]
Mechanical conditions in the internal stabilization of proximal tibial defects [J].
Duda, GN ;
Mandruzzato, F ;
Heller, M ;
Kassi, JP ;
Khodadadyan, C ;
Haas, NP .
CLINICAL BIOMECHANICS, 2002, 17 (01) :64-72
[10]
Mechanical boundary conditions of fracture healing: borderline indications in the treatment of unreamed tibial nailing [J].
Duda, GN ;
Mandruzzato, F ;
Heller, M ;
Goldhahn, J ;
Moser, R ;
Hehli, M ;
Claes, L ;
Haas, NP .
JOURNAL OF BIOMECHANICS, 2001, 34 (05) :639-650