Randomized study of the safety and clinical utility of rotational angiography versus standard angiography in the diagnosis of coronary artery disease

被引:63
作者
Maddux, JT
Wink, O
Messenger, JC
Groves, BM
Liao, R
Strzeiczyk, J
Chen, SY
Carroll, JD
机构
[1] Univ Colorado, Hlth Sci Ctr, Div Cardiol, Denver, CO 80262 USA
[2] Philips Med Syst N Amer, Bothell, WA USA
[3] Univ Colorado, Hlth Sci Ctr, Radiol Sci Div, Dept Radiol, Denver, CO USA
关键词
angiography; coronary artery disease;
D O I
10.1002/ccd.20036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluates the safety and clinical utility of rotational angiography in the diagnosis of coronary artery disease. High-speed rotational angiography is a newly available angiographic modality that gives a dynamic multiple-angle perspective of the coronary tree during a single contrast injection. We prospectively randomized 56 patients referred for diagnostic coronary angiography to either standard or rotational angiography. Contrast and radiation utilization were compared between the two groups. The number of additional cine acquisitions needed was used to determine adequacy of the diagnostic study protocol. Rotational angiography was successfully completed in all subjects. There was a 33% reduction in contrast utilization in the rotational group as compared to the standard group (35.6 +/- 12.6 vs. 52.8 +/- 10.7 ml, respectively; P < 0.0001). Additionally, there was a 28% reduction in total radiation exposure in the rotational group as compared to the standard group (39.0 +/- 18.5 vs. 53.9 +/- 23.4 Gycm(2), respectively; P = 0.01). Total whole-body radiation exposure to the primary operator was 144 mrem with rotational angiography and 170 mrem with standard angiography. Procedure time tended to be shorter for rotational angiography (353.9 +/- 146.7 vs. 396.8 +/- 165.8 s; P = 0.3). Rotational coronary angiography can be rapidly performed in any patient and provides a significant reduction in contrast and radiation utilization while at the same time providing adequate angiographic data to complement or replace standard coronary angiography in the evaluation of coronary artery disease. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 14 条
[1]   CORONARY-ARTERY NARROWING IN CORONARY HEART-DISEASE - COMPARISON OF CINEANGIOGRAPHIC AND NECROPSY FINDINGS [J].
ARNETT, EN ;
ISNER, JM ;
REDWOOD, DR ;
KENT, KM ;
BAKER, WP ;
ACKERSTEIN, H ;
ROBERTS, WC .
ANNALS OF INTERNAL MEDICINE, 1979, 91 (03) :350-356
[2]   Magnitude and consequences of error in coronary angiography interpretation (The ACRE study) [J].
Banerjee, S ;
Crook, AM ;
Dawson, JR ;
Timmis, AD ;
Hemingway, H .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (03) :309-314
[3]   INTRAVASCULAR ULTRASOUND VERSUS ANGIOGRAPHY FOR MEASUREMENT OD LUMINAL DIAMETERS IN NORMAL AND DISEASED CORONARY-ARTERIES [J].
DESCHEERDER, I ;
DEMAN, F ;
HERREGODS, MC ;
WILCZEK, K ;
BARRIOS, L ;
RAYMENANTS, E ;
DESMET, W ;
DEGEEST, H ;
PIESSENS, J .
AMERICAN HEART JOURNAL, 1994, 127 (02) :243-251
[4]   ACCURACY OF ANGIOGRAPHIC DETERMINATION OF LEFT MAIN CORONARY ARTERIAL NARROWING - ANGIOGRAPHIC-HISTOLOGIC CORRELATIVE ANALYSIS IN 28 PATIENTS [J].
ISNER, JM ;
KISHEL, J ;
KENT, KM ;
RONAN, JA ;
ROSS, AM ;
ROBERTS, WC .
CIRCULATION, 1981, 63 (05) :1056-1064
[5]   Usefulness of rotational spin for coronary angiography in patients with advanced renal insufficiency [J].
Kuon, E ;
Niederst, PN ;
Dahm, JB .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (04) :369-373
[6]   Effect of variability in the interpretation of coronary angiograms on the appropriateness of use of coronary revascularisation procedures [J].
Leape, LL ;
Park, RE ;
Bashore, TM ;
Harrison, JK ;
Davidson, CJ ;
Brook, RH .
AMERICAN HEART JOURNAL, 2000, 139 (01) :106-113
[7]   ATHEROSCLEROSIS IN ANGIOGRAPHICALLY NORMAL CORONARY-ARTERY REFERENCE SEGMENTS - AN INTRAVASCULAR ULTRASOUND STUDY WITH CLINICAL CORRELATIONS [J].
MINTZ, GS ;
PAINTER, JA ;
PICHARD, AD ;
KENT, KM ;
SATLER, LF ;
POPMA, JJ ;
CHUANG, YC ;
BUCHER, TA ;
SOKOLOWICZ, LE ;
LEON, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) :1479-1485
[8]   ANGIOSCOPIC CORONARY MACROMORPHOLOGY IN PATIENTS WITH ACUTE CORONARY DISORDERS [J].
MIZUNO, K ;
MIYAMOTO, A ;
SATOMURA, K ;
KURITA, A ;
ARAI, T ;
SAKURADA, M ;
YANAGIDA, S ;
NAKAMURA, H .
LANCET, 1991, 337 (8745) :809-812
[9]  
National Council on Radiation Protection and Measurements, 1990, IMPL PRINC LOW REAS
[10]   INTRAVASCULAR ULTRASOUND ASSESSMENT OF LUMEN SIZE AND WALL MORPHOLOGY IN NORMAL SUBJECTS AND PATIENTS WITH CORONARY-ARTERY DISEASE [J].
NISSEN, SE ;
GURLEY, JC ;
GRINES, CL ;
BOOTH, DC ;
MCCLURE, R ;
BERK, M ;
FISCHER, C ;
DEMARIA, AN .
CIRCULATION, 1991, 84 (03) :1087-1099