Finite element analysis on longitudinal and radial functionally graded femoral prosthesis

被引:23
作者
Oshkour, Azim Ataollahi [1 ]
Abu Osman, N. A. [2 ]
Davoodi, M. M. [2 ]
Yau, Y. H. [1 ]
Tarlochan, F. [3 ]
Abas, W. A. B. Wan [2 ]
Bayat, M. [4 ]
机构
[1] Univ Malaya, Fac Engn, Dept Mech Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Fac Engn, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
[3] Univ Tenaga Nas, Ctr Innovat & Design, Kajang, Malaysia
[4] Aalborg Univ, Dept Civil Engn, Aalborg, Denmark
关键词
finite element analysis; stress shielding; strain energy; total hip replacement; femoral prosthesis; HIP-PROSTHESIS; FATIGUE BEHAVIOR; DESIGN; STEM; BONE; FEMUR; OPTIMIZATION; REPLACEMENT; FABRICATION; COMPOSITES;
D O I
10.1002/cnm.2583
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
This study focused on developing a 3D finite element model of functionally graded femoral prostheses to decrease stress shielding and to improve total hip replacement performance. The mechanical properties of the modeled functionally graded femoral prostheses were adjusted in the sagittal and transverse planes by changing the volume fraction gradient exponent. Prostheses with material changes in the sagittal and transverse planes were considered longitudinal and radial prostheses, respectively. The effects of cemented and noncemented implantation methods were also considered in this study. Strain energy and von Mises stresses were determined at the femoral proximal metaphysis and interfaces of the implanted femur components, respectively. Results demonstrated that the strain energy increased proportionally with increasing volume fraction gradient exponent, whereas the interface stresses decreased on the prostheses surfaces. A limited increase was also observed at the surfaces of the bone and cement. The periprosthetic femur with a noncemented prosthesis exhibited higher strain energy than with a cemented prosthesis. Radial prostheses implantation displayed more strain energy than longitudinal prostheses implantation in the femoral proximal part. Functionally graded materials also increased strain energy and exhibited promising potentials as substitutes of conventional materials to decrease stress shielding and to enhance total hip replacement lifespan. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:1412 / 1427
页数:16
相关论文
共 35 条
[1]
Cement mantle stress under retroversion torque at heel-strike [J].
Afsharpoya, B. ;
Barton, D. C. ;
Fisher, J. ;
Purbach, B. ;
Wroblewski, M. ;
Stewart, T. D. .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (10) :1323-1330
[2]
Akay M, 1996, J BIOMED MATER RES, V31, P167
[3]
Fabrication and mechanical properties of Al2O3/SiC/ZrO2 functionally graded material by electrophoretic deposition [J].
Askari, E. ;
Mehrali, M. ;
Metselaar, I. H. S. C. ;
Kadri, N. A. ;
Rahman, Md. M. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 12 :144-150
[4]
Thermoelastic solution of a functionally graded variable thickness rotating disk with bending based on the first-order shear deformation theory [J].
Bayat, M. ;
Sahari, B. B. ;
Saleem, M. ;
Ali, Aidy ;
Wong, S. V. .
THIN-WALLED STRUCTURES, 2009, 47 (05) :568-582
[5]
Bayat M., 2008, LINEAR NONLINEAR THE
[6]
Design of a biomimetic polymer-composite hip prosthesis [J].
Bougherara, Habiba ;
Bureau, Martin ;
Campbell, Melissa ;
Vadean, Aurelian ;
Yahia, L'Hocine .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 82A (01) :27-40
[7]
Furlong Hydroxyapatite-Coated Hip Prosthesis vs the Charnley Cemented Hip Prosthesis [J].
Chandran, Prakash ;
Azzabi, Mohamed ;
Miles, Jeremy ;
Andrews, Mark ;
Bradley, John .
JOURNAL OF ARTHROPLASTY, 2010, 25 (01) :52-57
[8]
Polymer-based composite hip prostheses [J].
De Santis, R ;
Ambrosio, L ;
Nicolais, L .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2000, 79 (1-4) :97-102
[9]
Modelling bone tissue fracture and healing:: a review [J].
Doblaré, M ;
García, JM ;
Gómez, MJ .
ENGINEERING FRACTURE MECHANICS, 2004, 71 (13-14) :1809-1840
[10]
Probabilistic finite element analysis of the uncemented hip replacement-effect of femur characteristics and implant design geometry [J].
Dopico-Gonzalez, Carolina ;
New, Andrew M. ;
Browne, Martin .
JOURNAL OF BIOMECHANICS, 2010, 43 (03) :512-520