A tapered hollow metallic microneedle array using backside exposure of SU-8

被引:153
作者
Kim, K [1 ]
Park, DS
Lu, HM
Che, W
Kim, K [1 ]
Lee, JB
Ahn, CH
机构
[1] Univ Texas, Erik Jonsson Sch Engn & Comp Sci, Richardson, TX 75083 USA
[2] Tongmyung Univ Informat Technol, Sch Informat Engn, Pusan, South Korea
[3] Kyungwon Univ, Dept Elect & Informat Engn, Seongnam, South Korea
[4] Univ Cincinnati, Dept Elect Engn & Comp Sci, Cincinnati, OH 45221 USA
关键词
D O I
10.1088/0960-1317/14/4/021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel fabrication process for a tapered hollow metallic microneedle array using backside exposure of SU-8, and analytic solutions of critical buckling of a tapered hollow microneedle. An SU-8 mesa was formed on a Pyrex glass substrate and another SU-8 layer, which was spun on top of the SU-8 mesa, was exposed through the backside of the glass substrate. An array of SU-8 tapered pillar structures, with angles in the range of 3.1degrees-5degrees, was formed on top of the SU-8 mesa. Conformal electrodeposition of metal was carried out followed by a mechanical polishing using a planarizing polymeric layer. All organic layers were then removed to create a metallic hollow microneedle array with a fluidic reservoir on the backside. Both 200 mum and 400 mum tall, 10 by 10 arrays of metallic microneedles with inner diameters of the tip in the range of 33.6-101 mum and wall thickness of 10-20 mum were fabricated. Analytic solutions of the critical buckling of arbitrary-angled truncated cone-shaped columns are also presented. It was found that a single 400 Am tall hollow cylindrical microneedle made of electroplated nickel with a wall thickness of 20 mum, a tapered angle of 3.08degrees and a tip inner diameter of 33.6 mum has a critical buckling force of 1.8 N. This analytic solution can be used for square or rectangular cross-sectioned column structures with proper modifications.
引用
收藏
页码:597 / 603
页数:7
相关论文
共 12 条
[1]   Disposable Smart lab on a chip for point-of-care clinical diagnostics [J].
Ahn, CH ;
Choi, JW ;
Beaucage, G ;
Nevin, JH ;
Lee, JB ;
Puntambekar, A ;
Lee, JY .
PROCEEDINGS OF THE IEEE, 2004, 92 (01) :154-173
[2]  
[Anonymous], 1985, ENCY MED HIST
[3]  
CHANDRASEKARAN S, 2003, J MEMS, V12, P288
[4]  
FRITZ T, 2000, 3 INT C EXH DIG MICR, P752
[5]   Micromachined needles for the transdermal delivery of drugs [J].
Henry, S ;
McAllister, DV ;
Allen, MG ;
Prausnitz, MR .
MICRO ELECTRO MECHANICAL SYSTEMS - IEEE ELEVENTH ANNUAL INTERNATIONAL WORKSHOP PROCEEDINGS, 1998, :494-498
[6]   RATES OF NEEDLE-STICK INJURY CAUSED BY VARIOUS DEVICES IN A UNIVERSITY HOSPITAL [J].
JAGGER, J ;
HUNT, EH ;
BRANDELNAGGAR, J ;
PEARSON, RD .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (05) :284-288
[7]   Silicon-processed microneedles [J].
Lin, LW ;
Pisano, AP .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1999, 8 (01) :78-84
[8]  
McAllsiter D.V., 1999, 10 INT C SOL STAT SE, P1098
[9]   ULTRASOUND-MEDIATED TRANSDERMAL PROTEIN DELIVERY [J].
MITRAGOTRI, S ;
BLANKSCHTEIN, D ;
LANGER, R .
SCIENCE, 1995, 269 (5225) :850-853
[10]   Building thick photoresist structures from the bottom up [J].
Peterman, MC ;
Huie, P ;
Bloom, DM ;
Fishman, HA .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (03) :380-382