Determination of cadmium and lead at low levels by using preconcentration at fullerene coupled to thermospray flame furnace atomic absorption spectrometry

被引:73
作者
Pereira, MG
Pereira, ER
Berndt, H
Arruda, MAZ
机构
[1] Univ Estadual Campinas, Inst Quim, Dept Quim Analit, BR-13084971 Campinas, SP, Brazil
[2] Inst Spektrochem & Angew Spektroskopie, D-44139 Dortmund, Germany
关键词
cadmium; lead; preconcentration; fullerene; thermospray flame furnace atomic absorption spectrometry;
D O I
10.1016/j.sab.2003.12.012
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A new and sensitive method for Cd and Pb determinations, based on the coupling of thermospray flame furnace atomic absorption spectrometry and a preconcentrator system, was developed. The procedure comprised the chelating of Cd and Pb with ammonium pyrrolidinedithiocarbamate with posterior adsorption of the chelates on a mixture (40 mg) of C-60 and C-70 at a flow rate of 2.0 ml min(-1). These chelates were eluted from the adsorbent by passing a continuous flow of ethanol (80% v/v) at 0.9 ml min(-1) to a nickel tube placed in an air/acetylene flame. After sample introduction into the tube by using a ceramic capillary (0.5 mm i.d.). the analytical signals were registered as peak height. Under these conditions, improvement factors in detectability of 675 and 200 were obtained for Cd and Pb, respectively, when compared to conventional flame atomic absorption spectrometry. Spiked samples (mineral and tap waters) and drinking water containing natural concentrations of Cd were employed for evaluating accuracy by comparing the results obtained from the proposed methodology with those using electrothermal atomic absorption spectrometry. In addition, certified reference materials (rye grass, CRM 281 and pig kidney, CRM 186) were also adopted for the accuracy tests. Due to the good linearity ranges for Cd (0.5-5.0 mug l(-1)) and Pb (10-250 mug l(-1)), samples with different concentrations could be analyzed. Detection limits of 0.1 and 2.4 mug l(-1) were obtained for Cd and Pb, respectively, and RSD values <4.5% were observed (n = 10). Finally, a sample throughput of 24 determinations per hour was possible. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:515 / 521
页数:7
相关论文
共 27 条
[1]  
ALFKHAMI A, 2001, ANAL CHIM ACTA, V437, P17
[2]  
[Anonymous], 1987, ANALYST, V112, P199
[3]   Speciation of lead in environmental waters by preconcentration on a new fullerene derivative [J].
Baena, JR ;
Gallego, M ;
Valcárcel, M .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1519-1524
[4]   Fullerenes in the analytical sciences [J].
Baena, JR ;
Gallego, M ;
Valcárcel, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (03) :187-198
[5]   Determination of iron and nickel by flame atomic absorption spectrophotometry after preconcentration on Saccharomyces cerevisiae immobilized sepiolite [J].
Bag, H ;
Lale, M ;
Turker, AR .
TALANTA, 1998, 47 (03) :689-696
[6]   Separation and speciation of Cr(III) and Cr(VI) with Saccharomyces cerevisiae immobilized on sepiolite and determination of both species in water by FAAS [J].
Bag, H ;
Türker, AR ;
Lale, M ;
Tunçeli, A .
TALANTA, 2000, 51 (05) :895-902
[7]  
BURGERA JL, 1989, FLOW INJECTION ATOMI, V7
[8]   Flow injection determination of Pb and Cd traces with graphite furnace atomic absorption spectrometry [J].
Colognesi, M ;
Abollino, O ;
Aceto, M ;
Sarzanini, C ;
Mentasti, E .
TALANTA, 1997, 44 (05) :867-875
[9]   Improvements in thermospray flame furnace atomic absorption spectrometry [J].
Davies, J ;
Berndt, H .
ANALYTICA CHIMICA ACTA, 2003, 479 (02) :215-223
[10]   An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy [J].
Ferreira, SLC ;
Lemos, VA ;
Moreira, BC ;
Costa, ACS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :259-264