Dual energy X-ray absorptiometry measurements in small subjects: Conditions affecting clinical measurements

被引:17
作者
Koo, WWK
Hockman, EM
Hammami, M
机构
[1] Univ Tennessee, Dept Pediat, Memphis, TN USA
[2] Univ Tennessee, Dept Obstet & Gynecol, Memphis, TN 38103 USA
[3] Wayne State Univ, Dept Pediat Obstet & Gynecol, Detroit, MI USA
关键词
infant; bone; fat; lean tissue; body composition; ash; calcium;
D O I
10.1080/07315724.2004.10719363
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: To document the clinical and experimental situations that may affect DXA measurements in small subjects. Methods: 49 piglets (886g to 1100g) had measurements with either of two pencil beam densitometers (QDR 1000W and QDR 2000 Plus, Hologic Inc, Waltham, MA) using commercial infant (TWB) and adult whole body (AWB) software v5.71p and v5.71 respectively. AWB scans were analyzed with three additional software versions. 35 infants (2115 to 11564g) had IWB measurements. Results: DXA measurements of total weight, bone mineral content, bone area, bone mineral density, fat and lean mass from IWB scans (all piglets) and from AWB scans (piglets > 12 kg) were highly reproducible (p < 0.001). A statistically significant change occurred in at least one of the DXA measurements from the use of different platforms, variations in the amount and placement of covering (e.g., blanket), placement of the external calibration standard, presence of radiographic contrast material, presence of movement artifact, delivery of an intravenous fluid bolus prior to scanning or improper delineation of external calibration standard during analysis. Additionally, results varied amongst different versions of software as well as between IWB and AWB softwares. Conclusion: In small subjects, consistency in the DXA techniques is paramount for valid and meaningful comparison of DXA data in bone mass and body composition.
引用
收藏
页码:212 / 219
页数:8
相关论文
共 25 条
[1]   Growth and body composition in infants with bronchopulmonary dysplasia up to 3 months corrected age: A randomized trial of a high-energy nutrient-enriched formula fed after hospital discharge [J].
Brunton, JA ;
Saigal, S ;
Atkinson, SA .
JOURNAL OF PEDIATRICS, 1998, 133 (03) :340-345
[2]   Fat mass in infants and toddlers: Comparability of total body water, total body potassium, total body electrical conductivity, and dual-energy X-ray absorptiometry [J].
Butte, N ;
Heinz, C ;
Hopkinson, J ;
Wong, W ;
Shypailo, R ;
Ellis, K .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1999, 29 (02) :184-189
[3]   Body composition during the first 2 years of life: An updated reference [J].
Butte, NF ;
Hopkinson, JM ;
Wong, WW ;
Smith, EO ;
Ellis, KJ .
PEDIATRIC RESEARCH, 2000, 47 (05) :578-585
[4]   Infant feeding mode affects early growth and body composition [J].
Butte, NF ;
Wong, WW ;
Hopkinson, JM ;
Smith, EO ;
Ellis, KJ .
PEDIATRICS, 2000, 106 (06) :1355-1366
[5]   Fan beam dual energy X-ray absorptiometry body composition measurements in piglets [J].
Chauhan, S ;
Koo, WWK ;
Hammami, M ;
Hockman, EM .
JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2003, 22 (05) :408-414
[6]   Neonatal body composition:: Dual-energy X-ray absorptiometry, magnetic resonance imaging, and three-dimensional chemical shift imaging versus chemical analysis in piglets [J].
Fusch, C ;
Slotboom, J ;
Fuehrer, U ;
Schumacher, R ;
Keisker, A ;
Zimmermann, W ;
Moessinger, A ;
Boesch, C ;
Blum, J .
PEDIATRIC RESEARCH, 1999, 46 (04) :465-473
[7]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[8]  
Koo WWK, 2000, ANN NY ACAD SCI, V904, P383
[9]  
KOO WWK, 1995, J BONE MINER RES, V10, P1111
[10]   Body composition in human infants at birth and postnatally [J].
Koo, WWK ;
Walters, JC ;
Hockman, EM .
JOURNAL OF NUTRITION, 2000, 130 (09) :2188-2194