Differences in the erythrocyte aggregation level between veins and arteries of normolipidemic and hyperlipidemic individuals

被引:24
作者
Cloutier, G
Weng, XD
Roederer, GO
Allard, L
Tardif, F
Beaulieu, R
机构
[1] INST RECH CLIN MONTREAL,LAB HYPERLIPIDEMIA & ATHEROSCLEROSIS,MONTREAL,PQ H2W 1R7,CANADA
[2] INST RECH CLIN MONTREAL,SERV ECHODOPPLER,MONTREAL,PQ H2W 1R7,CANADA
[3] MONTREAL GEN HOSP,HOTEL DIEU,DIV ONCOL & HEMATOL,MONTREAL,PQ H3G 1A4,CANADA
基金
英国医学研究理事会;
关键词
spontaneous echo contrast; acoustic backscattering; red cell aggregation; power Doppler ultrasound; hyperlipidemia; blood flow; hemodynamics; biorheology; SPONTANEOUS ECHO CONTRAST; MITRAL-VALVE DISEASE; SPONTANEOUS ECHOCARDIOGRAPHIC CONTRAST; SMOKE-LIKE ECHO; DOPPLER ULTRASOUND; SHEAR RATE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; CEREBROVASCULAR-DISEASE; DILATED CARDIOMYOPATHY; PLATELET-AGGREGATION;
D O I
10.1016/S0301-5629(97)00199-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objectives of this study were to detect differences in the Doppler power backscattered by blood in vivo, and to identify factors affecting the backscattered power, The main hypothesis was that variations in the erythrocyte aggregation level between veins and arteries of normolipidemic and hyperlipidemic individuals can be detected with power Doppler ultrasound, Doppler measurements were performed at 5 MHz, with an Acuson 128 XP/10 system, over the carotid artery and jugular vein, external iliac artery and vein, common femoral artery and vein and popliteal artery and vein, Doppler signals were recorded at the center of each vessel to optimize the detection of erythrocyte aggregation, and processed off-line to obtain the backscattered power, The power of each recording was compensated for Doppler gain differences, tissue attenuation,vith depth and transmitted po,ver variations occurring with pulse-repetition interval modifications, Results showed statistically stronger backscattered power in veins compared to arteries for the iliac, femoral and popliteal sites, In comparison with healthy subjects, stronger powers were observed in hyperlipidemic patients for the femoral and popliteal sites, Power differences were also found between peripheral measurements, On the other hand, no difference was observed between the power measured in the carotid artery and jugular vein for both groups of individuals, Multiple linear regression analyses were performed to identify factors affecting the backscattered power, Results showed a correlation (r) of 71.2% between the Doppler power in the femoral vein and the linear combination of two parameters: an erythrocyte aggregation index S-10 measured with a laser scattering method, and the diameter of the vessel measured on B-mode images. Statistically significant linear correlation levels were also found between S-10 and the Doppler power in various vessels, In conclusion, this study showed that power Doppler differences exist in vivo in large vessels between veins and arteries of normolipidemic and hyperlipidemic individuals. The Doppler power variations were also shown to be related to erythrocyte aggregation. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1383 / 1393
页数:11
相关论文
共 39 条
  • [1] SMOKE-LIKE ECHO IN THE LEFT ATRIAL CAVITY IN MITRAL-VALVE DISEASE - ITS FEATURES AND SIGNIFICANCE
    BEPPU, S
    NIMURA, Y
    SAKAKIBARA, H
    NAGATA, S
    PARK, YD
    IZUMI, S
    UEOKA, M
    MASUDA, Y
    NAKASONE, I
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (04) : 744 - 749
  • [2] LEFT ATRIAL SPONTANEOUS ECHO CONTRAST - A CLINICAL AND ECHOCARDIOGRAPHIC ANALYSIS
    BLACK, IW
    HOPKINS, AP
    LEE, LCL
    WALSH, WF
    JACOBSON, BM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (02) : 398 - 404
  • [3] SPONTANEOUS ECHO CONTRAST AND HEMORHEOLOGIC ABNORMALITIES IN CEREBROVASCULAR-DISEASE
    BRILEY, DP
    GIRAUD, GD
    BEAMER, NB
    SPEAR, EM
    GRAUER, SE
    EDWARDS, JM
    CLARK, WM
    SEXTON, GJ
    COULL, BM
    [J]. STROKE, 1994, 25 (08) : 1564 - 1569
  • [4] Characterization of blood flow turbulence with pulsed-wave and power Doppler ultrasound imaging
    Cloutier, G
    Allard, L
    Durand, LG
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 318 - 325
  • [5] Power Doppler ultrasound evaluation of the shear rate and shear stress dependences of red blood cell aggregation
    Cloutier, G
    Qin, Z
    Durand, LG
    Teh, BG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (05) : 441 - 450
  • [6] LEFT ATRIAL SPONTANEOUS ECHO CONTRAST IN MITRAL-VALVE DISEASE - AN INDICATOR FOR AN INCREASED THROMBOEMBOLIC RISK
    DANIEL, WG
    NELLESSEN, U
    SCHRODER, E
    NONNASTDANIEL, B
    BEDNARSKI, P
    NIKUTTA, P
    LICHTLEN, PR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (06) : 1204 - 1211
  • [7] SPONTANEOUS ECHO CONTRAST IN THE DESCENDING AORTA DETECTED BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    DEFILIPPI, CR
    LACKER, M
    GRAYBURN, PA
    BRICKNER, ME
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (04) : 410 - 411
  • [8] DETECTION OF SPONTANEOUS ECHOCARDIOGRAPHIC CONTRAST WITHIN THE LEFT ATRIUM BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY - SPONTANEOUS ECHOCARDIOGRAPHIC CONTRAST
    ERBEL, R
    STERN, H
    EHRENTHAL, W
    SCHREINER, G
    TREESE, N
    KRAMER, G
    THELEN, M
    SCHWEIZER, P
    MEYER, J
    [J]. CLINICAL CARDIOLOGY, 1986, 9 (06) : 245 - 252
  • [9] SPONTANEOUS ECHOCARDIOGRAPHIC CONTRAST IN THE THORACIC AORTA - FACTORS ASSOCIATED WITH ITS OCCURRENCE AND ITS ASSOCIATION WITH EMBOLIC EVENTS
    FINKELHOR, RS
    LAMONT, WE
    RAMANAVARAPU, SK
    BAHLER, RC
    [J]. AMERICAN HEART JOURNAL, 1995, 130 (06) : 1254 - 1258
  • [10] FORCONI S, 1979, J CARDIOVASC SURG, V20, P379