Differences in the erythrocyte aggregation level between veins and arteries of normolipidemic and hyperlipidemic individuals

被引:24
作者
Cloutier, G
Weng, XD
Roederer, GO
Allard, L
Tardif, F
Beaulieu, R
机构
[1] INST RECH CLIN MONTREAL,LAB HYPERLIPIDEMIA & ATHEROSCLEROSIS,MONTREAL,PQ H2W 1R7,CANADA
[2] INST RECH CLIN MONTREAL,SERV ECHODOPPLER,MONTREAL,PQ H2W 1R7,CANADA
[3] MONTREAL GEN HOSP,HOTEL DIEU,DIV ONCOL & HEMATOL,MONTREAL,PQ H3G 1A4,CANADA
基金
英国医学研究理事会;
关键词
spontaneous echo contrast; acoustic backscattering; red cell aggregation; power Doppler ultrasound; hyperlipidemia; blood flow; hemodynamics; biorheology; SPONTANEOUS ECHO CONTRAST; MITRAL-VALVE DISEASE; SPONTANEOUS ECHOCARDIOGRAPHIC CONTRAST; SMOKE-LIKE ECHO; DOPPLER ULTRASOUND; SHEAR RATE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; CEREBROVASCULAR-DISEASE; DILATED CARDIOMYOPATHY; PLATELET-AGGREGATION;
D O I
10.1016/S0301-5629(97)00199-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objectives of this study were to detect differences in the Doppler power backscattered by blood in vivo, and to identify factors affecting the backscattered power, The main hypothesis was that variations in the erythrocyte aggregation level between veins and arteries of normolipidemic and hyperlipidemic individuals can be detected with power Doppler ultrasound, Doppler measurements were performed at 5 MHz, with an Acuson 128 XP/10 system, over the carotid artery and jugular vein, external iliac artery and vein, common femoral artery and vein and popliteal artery and vein, Doppler signals were recorded at the center of each vessel to optimize the detection of erythrocyte aggregation, and processed off-line to obtain the backscattered power, The power of each recording was compensated for Doppler gain differences, tissue attenuation,vith depth and transmitted po,ver variations occurring with pulse-repetition interval modifications, Results showed statistically stronger backscattered power in veins compared to arteries for the iliac, femoral and popliteal sites, In comparison with healthy subjects, stronger powers were observed in hyperlipidemic patients for the femoral and popliteal sites, Power differences were also found between peripheral measurements, On the other hand, no difference was observed between the power measured in the carotid artery and jugular vein for both groups of individuals, Multiple linear regression analyses were performed to identify factors affecting the backscattered power, Results showed a correlation (r) of 71.2% between the Doppler power in the femoral vein and the linear combination of two parameters: an erythrocyte aggregation index S-10 measured with a laser scattering method, and the diameter of the vessel measured on B-mode images. Statistically significant linear correlation levels were also found between S-10 and the Doppler power in various vessels, In conclusion, this study showed that power Doppler differences exist in vivo in large vessels between veins and arteries of normolipidemic and hyperlipidemic individuals. The Doppler power variations were also shown to be related to erythrocyte aggregation. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1383 / 1393
页数:11
相关论文
共 39 条
  • [21] MAHONY C, 1994, J ULTRAS MED, V13, P443
  • [22] RESOLUTION OF SPONTANEOUS CONTRAST WITH PLATELET DISAGGREGATORY THERAPY (TRIFLUOPERAZINE)
    MAHONY, C
    SUBLETT, KL
    HARRISON, MR
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (13) : 1009 - 1010
  • [23] MAIURI F, 1995, EUR J ULTRASOUND, V2, P261
  • [24] McDicken WN., 1991, DIAGNOSTIC ULTRASONI, VThird
  • [25] Differences in peripheral arterial and venous hemorheologic parameters
    Mokken, FC
    vanderWaart, FJM
    Henny, CP
    Goedhart, PT
    Gelb, AW
    [J]. ANNALS OF HEMATOLOGY, 1996, 73 (03) : 135 - 137
  • [26] INTRACAVITARY ECHOES IN THE AORTIC-ARCH IN TYPE-III AORTIC DISSECTION
    PANIDIS, IP
    KOTLER, MN
    MINTZ, GS
    ROSS, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (08) : 1159 - 1160
  • [27] PIGNON B, 1994, NOUV REV FR HEMATOL, V36, P431
  • [28] Rampling M.W., 1988, Clinical blood rheology, V1, P45
  • [29] A WALL-LESS VESSEL PHANTOM FOR DOPPLER ULTRASOUND STUDIES
    RICKEY, DW
    PICOT, PA
    CHRISTOPHER, DA
    FENSTER, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (09) : 1163 - 1176
  • [30] Riha P, 1996, CLIN HEMORHEOL, V16, P43