A WALL-LESS VESSEL PHANTOM FOR DOPPLER ULTRASOUND STUDIES

被引:208
作者
RICKEY, DW
PICOT, PA
CHRISTOPHER, DA
FENSTER, A
机构
[1] JOHN P ROBARTS RES INST,IMAGING RES LABS,LONDON,ON N6A 5K8,CANADA
[2] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON,ON,CANADA
[3] UNIV HOSP ONTARIO,DEPT RADIOL,LONDON,ON,CANADA
[4] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO,ON,CANADA
[5] SUNY HLTH SCI CTR,TORONTO,ON,CANADA
基金
英国医学研究理事会;
关键词
DOPPLER ULTRASOUND; DOPPLER SPECTRA; FLOW PHANTOM; BLOOD MIMIC; TISSUE MIMIC;
D O I
10.1016/0301-5629(95)00044-5
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Doppler ultrasound flow measurement techniques are often validated using phantoms that simulate the vasculature, surrounding tissue and blood. Many researchers use rubber tubing to mimic blood vessels because of the realistic acoustic impedance, robust physical properties and wide range of available sizes. However, rubber tubing has a very high acoustic attenuation, which may introduce artefacts into the Doppler measurements. We describe the construction of a wall-less vessel phantom that eliminates the highly attenuating wall and reduces impedance mismatches between the vessel lumen and tissue mimic. An agar-based tissue mimic and a blood mimic are described and their acoustic attenuation coefficients and velocities are characterised. The high attenuation of the latex rubber tubing resulted in pronounced shadowing in B-mode images; however, an image of a wall-less vessel phantom did not show any shadowing. We show that the effects of the highly attenuating latex rubber vessels on Doppler amplitude spectra depend on the vessel diameter and ultrasound beam width. In this study, only small differences were observed in spectra obtained from 0.6 cm inside diameter thin-wall latex, thick-wall latex and wall-less vessel phantoms. However, a computer model predicted that the spectrum obtained from a 0.3-cm inside diameter latex-all vessel would be significantly different than the spectrum obtained from a wall-less vessel phantom, thus resulting in an overestimation of the average fluid velocity. These results suggest that care must be taken to ensure that the Doppler measurements are not distorted by the highly attenuating wall material. In addition, the results show that a wall-less vessel phantom is preferable when measuring flow in small vessels.
引用
收藏
页码:1163 / 1176
页数:14
相关论文
共 37 条
  • [1] PERFORMANCE TESTS OF DOPPLER ULTRASOUND EQUIPMENT WITH A TISSUE AND BLOOD-MIMICKING PHANTOM
    BOOTE, EJ
    ZAGZEBSKI, JA
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 1988, 7 (03) : 137 - 147
  • [2] NEW ULTRASOUND TISSUE-EQUIVALENT MATERIAL
    BURLEW, MM
    MADSEN, EL
    ZAGZEBSKI, JA
    BANJAVIC, RA
    SUM, SW
    [J]. RADIOLOGY, 1980, 134 (02) : 517 - 520
  • [3] BURNS PN, 1985, RADIOL CLIN N AM, V23, P641
  • [4] DETERMINATION OF THE ACOUSTIC PROPERTIES OF BLOOD AND ITS COMPONENTS
    CARSTENSEN, EL
    LI, K
    SCHWAN, HP
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1953, 25 (02) : 286 - 289
  • [5] CHRISTOPHER DA, 1992, THESIS U TORONTO
  • [6] INFLUENCE OF BEAM PROFILE AND DEGREE OF INSONATION ON THE CW DOPPLER ULTRASOUND SPECTRUM AND MEAN VELOCITY
    COBBOLD, RSC
    VELTINK, PH
    JOHNSTON, KW
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (06): : 364 - 370
  • [7] ACCURACY OF COLOR DOPPLER ULTRASOUND VELOCITY-MEASUREMENTS IN SMALL VESSELS
    DEANE, CR
    FORSBERG, F
    THOMAS, N
    ROBERTS, VC
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (03): : 249 - 254
  • [8] AN INVITRO MODEL AND ITS APPLICATION FOR THE STUDY OF CAROTID DOPPLER SPECTRAL BROADENING
    DOUVILLE, Y
    JOHNSTON, KW
    KASSAM, M
    ZUECH, P
    COBBOLD, RSC
    JARES, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (04) : 347 - 356
  • [9] ANGLE INDEPENDENT DOPPLER COLOR IMAGING - DETERMINATION OF ACCURACY AND A METHOD OF DISPLAY
    FEI, DY
    FU, CT
    BREWER, WH
    KRAFT, KA
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (02) : 147 - 155
  • [10] A GEOMETRICALLY ACCURATE VASCULAR PHANTOM FOR COMPARATIVE-STUDIES OF X-RAY, ULTRASOUND, AND MAGNETIC-RESONANCE VASCULAR IMAGING - CONSTRUCTION AND GEOMETRICAL VERIFICATION
    FRAYNE, R
    GOWMAN, LM
    RICKEY, DW
    HOLDSWORTH, DW
    PICOT, PA
    DRANGOVA, M
    CHU, KC
    CALDWELL, CB
    FENSTER, A
    RUTT, BK
    [J]. MEDICAL PHYSICS, 1993, 20 (02) : 415 - 425