Nanostructured microcantilevers with functionalized cyclodextrin receptor phases: Self-assembled monolayers and vapor-deposited films

被引:56
作者
Tipple, CA
Lavrik, NV
Culha, M
Headrick, J
Datskos, P
Sepaniak, MJ [1 ]
机构
[1] Univ Tennessee, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
关键词
D O I
10.1021/ac020074o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is shown that the performance of microcantilver-based chemical sensors in a liquid environment is affected by altering cantilever surface morphology and receptor phase type and thickness. Self-assembled monolayers of thiolated beta-cyclodextrin (HM-beta-CD) and thin films of vapor-deposited heptakis (2,3-O-diacetyl-6-O-tertbutyl-dimethylsilyl)-beta-cyclodextrin (HDATB-beta-CD) were studied on smooth and nanostructured (dealloyed) gold-coated microcantilever surfaces. The dealloyed surface contains nanometer-sized features that enhance the transduction of molecular recognition events into cantilever response, as well as increase film stability for thicker films. Improvements in the limits of detection of the compound 2,3-dihydroxynaphthalene as great as 2 orders of magnitude have been achieved by manipulating surface morphology and film thickness. The observed response factors for the analytes studied varied from 0.02-604 nm/ppm, as determined by cantilever deflection. In general, calibration plots for the analytes were linear up to several hundred nanometers in cantilever deflections.
引用
收藏
页码:3118 / 3126
页数:9
相关论文
共 37 条
[1]   A cantilever array-based artificial nose [J].
Baller, MK ;
Lang, HP ;
Fritz, J ;
Gerber, C ;
Gimzewski, JK ;
Drechsler, U ;
Rothuizen, H ;
Despont, M ;
Vettiger, P ;
Battiston, FM ;
Ramseyer, JP ;
Fornaro, P ;
Meyer, E ;
Güntherodt, HJ .
ULTRAMICROSCOPY, 2000, 82 (1-4) :1-9
[2]   A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout [J].
Battiston, FM ;
Ramseyer, JP ;
Lang, HP ;
Baller, MK ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Güntherodt, HJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) :122-131
[3]  
Beck T, 2000, HRC-J HIGH RES CHROM, V23, P569
[4]   Surface stress in the self-assembly of alkanethiols on gold [J].
Berger, R ;
Delamarche, E ;
Lang, HP ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Guntherodt, HJ .
SCIENCE, 1997, 276 (5321) :2021-2024
[5]   Selectivity of chemical sensors based on micro-cantilevers coated with thin polymer films [J].
Betts, TA ;
Tipple, CA ;
Sepaniak, MJ ;
Datskos, PG .
ANALYTICA CHIMICA ACTA, 2000, 422 (01) :89-99
[6]  
Bicchi C, 1999, J MICROCOLUMN SEP, V11, P487, DOI 10.1002/(SICI)1520-667X(1999)11:7<487::AID-MCS1>3.0.CO
[7]  
2-B
[8]   Environmental sensors based on micromachined cantilevers with integrated read-out [J].
Boisen, A ;
Thaysen, J ;
Jensenius, H ;
Hansen, O .
ULTRAMICROSCOPY, 2000, 82 (1-4) :11-16
[9]   Multiple-input microcantilever sensors [J].
Britton, CL ;
Jones, RL ;
Oden, PI ;
Hu, Z ;
Warmack, RJ ;
Smith, SF ;
Bryan, WL ;
Rochelle, JM .
ULTRAMICROSCOPY, 2000, 82 (1-4) :17-21
[10]   MECHANISMS OF ENANTIOMERIC RESOLUTION IN CYCLODEXTRIN-MODIFIED CAPILLARY ELECTROPHORETIC SEPARATIONS OF BINAPHTHYL COMPOUNDS [J].
COPPER, CL ;
DAVIS, JB ;
SEPANIAK, MJ .
CHIRALITY, 1995, 7 (06) :401-408