Capillary gas chromatography coupled with negative ionization microplasma mass spectrometry for halogen-selective detection

被引:19
作者
Brede, C
Pedersen-Bjergaard, S
Lundanes, E
Greibrokk, T
机构
[1] Univ Oslo, Dept Chem, N-0315 Oslo, Norway
[2] Univ Oslo, Sch Pharm, N-0316 Oslo, Norway
关键词
D O I
10.1039/a904211c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gas chromatography was coupled with plasma mass spectrometry with a microplasma ion source for negative ion detection. The ion source, which was kept inside the high vacuum chamber of the mass spectrometer, was a rigid fused silica capillary tube containing a capacitively coupled radiofrequency helium plasma. This made the setup quite simple: eliminating the sampler-skimmer pressure-reducing interface traditionally used in plasma mass spectrometry. The present study describes the utilization of halogen-selective negative ion detection. A high selectivity of fluorine to hydrocarbon compounds (3 x 10(3)), and a highly sensitive detection for F, Cl, Br, and I (0.13-12 pg s(-1)), were obtained. The mechanisms of negative ion formation and breakdown were discussed in conjunction with the results that were achieved.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 31 条
[1]   Radiofrequency glow discharge as an ion source for gas chromatography with mass spectrometric detection [J].
Belkin, MA ;
Olson, LK ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1255-1261
[2]  
Brede C, 1998, HRC-J HIGH RES CHROM, V21, P633
[3]  
Brede C, 1998, HRC-J HIGH RES CHROM, V21, P282
[4]   Microplasma mass spectrometric detection in capillary gas chromatography [J].
Brede, C ;
Pedersen-Bjergaard, S ;
Lundanes, E ;
Greibrokk, T .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :513-518
[5]   Capillary gas chromatography coupled with microplasma mass spectrometry for organotin speciation [J].
Brede, C ;
Pedersen-Bjergaard, S ;
Lundanes, E ;
Greibrokk, T .
JOURNAL OF CHROMATOGRAPHY A, 1999, 849 (02) :553-562
[6]  
BREDE C, Patent No. 00048
[7]   EVALUATION OF LOW-PRESSURE INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR THE ANALYSIS OF GASEOUS SAMPLES [J].
CASTILLANO, TM ;
GIGLIO, JJ ;
EVANS, EH ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) :1335-1340
[8]   INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY FOR ELEMENTAL ANALYSIS AND ISOTOPE RATIO DETERMINATIONS IN INDIVIDUAL ORGANIC-COMPOUNDS SEPARATED BY GAS-CHROMATOGRAPHY [J].
CHONG, NS ;
HOUK, RS .
APPLIED SPECTROSCOPY, 1987, 41 (01) :66-74
[9]  
Christophorou L.G., 1984, ELECT MOL INTERACTIO, VI
[10]   LOW-PRESSURE HELIUM MICROWAVE-INDUCED PLASMA MASS-SPECTROMETRY FOR THE DETECTION OF HALOGENATED GAS-CHROMATOGRAPHIC EFFLUENTS [J].
CREED, JT ;
DAVIDSON, TM ;
SHEN, WL ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (02) :109-113