The high-quality aspects of magnified X-ray images recorded using MIRRORCLE-6X are reported. MIRRORCLE-6X is inherently suitable for hard X-ray imaging owing to its magnified projection X-ray imaging, micrometre-size X-ray source point, wide radiation emission angle, X-ray spectrum ranging from 10 keV to 6 MeV, natural refraction contrast imaging and high flux output. Images produced with 11 x geometrical magnification display a sharply enhanced edge effect when generated using a 25 mm rod electron target. Image contrast is enhanced 2 x owing to refraction when compared with absorption contrast images. An imitation tumour implanted in a human chest phantom was made clearly visible by using edge enhancement on images. Soft tissue becomes highly visible as a natural consequence of refraction contrast when using hard X-rays for imaging. The authors believe that novel imaging provided by MIRRORCLE makes it a superior instrument for medical diagnosis.
引用
收藏
页码:397 / 402
页数:6
相关论文
共 16 条
[1]
GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]
Born M., 1975, PRINCIPLES OPTICS
[3]
Transmission x-ray microscopy with 50 nm resolution installed at Ritsumeikan Synchrotron Radiation Center [J].
Hirai, A ;
Takemoto, K ;
Nishino, K ;
Niemann, B ;
Hettwer, M ;
Rudolph, D ;
Anderson, E ;
Attwood, D ;
Kern, DP ;
Nakayama, Y ;
Kihara, H .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 (1A) :274-278
[4]
Laser plasma soft X-ray microscope with Wolter mirrors for observation of biological specimens in air [J].
Hoshino, M ;
Aoki, S .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (2A) :989-994
[5]
Development of a two-dimensional imaging system for clinical applications of intravenous coronary angiography using intense synchrotron radiation produced by a multipole wiggler [J].
Hyodo, K ;
Ando, M ;
Oku, Y ;
Yamamoto, S ;
Takeda, T ;
Itai, Y ;
Ohtsuka, S ;
Sugishita, Y .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :1123-1126
[6]
A new method of analyzing edge effect in phase contrast imaging with incoherent X-rays [J].
Ishisaka, A ;
Ohara, H ;
Honda, C .
OPTICAL REVIEW, 2000, 7 (06) :566-572
[7]
Phase-contrast X-ray imaging using bath vertically and horizontally expanded synchrotron radiation X-rays with asymmetric Bragg reflection [J].
Kagoshima, Y ;
Tsusaka, Y ;
Yokoyama, K ;
Takai, K ;
Takeda, S ;
Matsui, J .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1999, 38 (4B) :L470-L472
[8]
Refraction-contrast imaging using undulator radiation at SPring-8 [J].
Suzuki, Y ;
Yagi, N ;
Umetani, K ;
Kohmura, Y ;
Yamasaki, K .
MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 :13-22
[9]
X-ray refraction-enhanced imaging and a method for phase retrieval for a simple object [J].
Suzuki, Y ;
Yagi, N ;
Uesugi, K .
JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 :160-165
[10]
Phase-contrast imaging using polychromatic hard X-rays [J].
Wilkins, SW ;
Gureyev, TE ;
Gao, D ;
Pogany, A ;
Stevenson, AW .
NATURE, 1996, 384 (6607) :335-338