Unbalanced versus balanced operation in an optical coherence tomography system

被引:79
作者
Podoleanu, AG [1 ]
机构
[1] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NR, Kent, England
关键词
D O I
10.1364/AO.39.000173
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The choice of a balanced optical coherence tomography (OCT) configuration versus an unbalanced OCT configuration with optimized reference-arm attenuation is discussed. The choice depends on the receiver noise, the fiber-end reflection R, and the power to the object. When OCT is used to investigate biological tissue an equivalent R' can be evaluated as the compound reflected light from tissue. In this case an additional parameter has to be considered: the confocal optical sectioning interval of the OCT system. (C) 2000 Optical Society of America OCIS codes: 170.4500, 170.1790, 230.5160, 070.6020, 060.2370, 030.4280.
引用
收藏
页码:173 / 182
页数:10
相关论文
共 23 条
[11]   Noise analysis of a combined optical coherence tomograph and a confocal scanning ophthalmoscope [J].
Podoleanu, AG ;
Jackson, DA .
APPLIED OPTICS, 1999, 38 (10) :2116-2127
[12]   Video-rate confocal scanning laser microscope for imaging human tissues in vivo [J].
Rajadhyaksha, M ;
Anderson, RR ;
Webb, RH .
APPLIED OPTICS, 1999, 38 (10) :2105-2115
[13]   In vivo video rate optical coherence tomography [J].
Rollins, AM ;
Kulkarni, MD ;
Yazdanfar, S ;
Ung-arunyawee, R ;
Izatt, JA .
OPTICS EXPRESS, 1998, 3 (06) :219-229
[14]   Model of optical coherence tomography of heterogeneous tissue [J].
Schmitt, JM ;
Knuttel, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (06) :1231-1242
[15]  
SCHMITT JM, 1993, P SOC PHOTO-OPT INS, V1889, P197, DOI 10.1117/12.155715
[16]   Penetration depth limits of in vivo confocal reflectance imaging [J].
Smithpeter, CL ;
Dunn, AK ;
Welch, AJ ;
Richards-Kortum, R .
APPLIED OPTICS, 1998, 37 (13) :2749-2754
[17]   A SIMPLE INTENSITY NOISE-REDUCTION TECHNIQUE FOR OPTICAL LOW-COHERENCE REFLECTOMETRY [J].
SORIN, WV ;
BANEY, DM .
IEEE PHOTONICS TECHNOLOGY LETTERS, 1992, 4 (12) :1404-1406
[18]   HIGH-SPEED OPTICAL COHERENCE DOMAIN REFLECTOMETRY [J].
SWANSON, EA ;
HUANG, D ;
HEE, MR ;
FUJIMOTO, JG ;
LIN, CP ;
PULIAFITO, CA .
OPTICS LETTERS, 1992, 17 (02) :151-153
[19]   Air-turbine driven optical low-coherence reflectometry at 28.6-kHz scan repetition rate [J].
Szydlo, J ;
Delachenal, N ;
Giannotti, R ;
Walti, R ;
Bleuler, H ;
Salathe, RP .
OPTICS COMMUNICATIONS, 1998, 154 (1-3) :1-4
[20]   PHASE-NOISE AND SHOT-NOISE LIMITED OPERATIONS OF LOW COHERENCE OPTICAL-TIME DOMAIN REFLECTOMETRY [J].
TAKADA, K ;
HIMENO, A ;
YUKIMATSU, K .
APPLIED PHYSICS LETTERS, 1991, 59 (20) :2483-2485