Visualization of sample introduction in liquid chromatographic columns - Contribution of a flow distributor on the sample band shape

被引:29
作者
Shalliker, RA
Broyles, BS
Guiochon, G
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
关键词
visualization; sample introduction; band profiles; flow distributor;
D O I
10.1016/S0021-9673(99)00852-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The contributions to the radial distribution of the sample concentration across the column inlet and to the axial band dispersion resulting from a column header containing a distributor were evaluated using a band-visualization process entailing matching the refractive indices of the stationary and mobile phases in a glass column. This study illustrates graphically how a distributor fitted to the column can increase the axial dispersion of the sample band compared to an inlet containing only a frit. The distributor did not provide a uniform sample distribution across the column. In fact, for 17-mm inner diameter columns and high-porosity frits, the distribution was no better than with the frit having no distributor. However, when low-porosity frits were employed, improved peak shapes were obtained with a distributor. In addition, we observed that the inlet header configuration influenced dramatically the flow stream established along the column. The radial distribution of the efficiency of the columns was nearly homogeneous for those having only a frit but not for those having also a distributor. For the latter, the efficiency decreased from the column axis to its wall. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:83 / 95
页数:13
相关论文
共 14 条
[1]   RADIAL DISPERSION FROM COMMERCIAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS INVESTIGATED WITH MICROVOLTAMMETRIC ELECTRODES [J].
BAUR, JE ;
KRISTENSEN, EW ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2334-2338
[2]   Visualization of sample introduction in liquid chromatography columns - The effect of the frit diameter [J].
Broyles, BS ;
Shalliker, RA ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (02) :367-382
[3]  
BROYLES BS, UNPUB
[4]   COMPARISON OF BROADENING PATTERNS IN REGULAR AND RADIALLY COMPRESSED LARGE-DIAMETER COLUMNS [J].
EON, CH .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :29-42
[5]   Column radial homogeneity in high-performance liquid chromatography [J].
Farkas, T ;
Sepaniak, MJ ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (02) :169-181
[6]   Contribution of the radial distribution of the flow velocity to band broadening in HPLC columns [J].
Farkas, T ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4592-4600
[7]   Radial distribution of the flow velocity, efficiency and concentration in a wide HPLC column [J].
Farkas, T ;
Sepaniak, MJ ;
Guiochon, G .
AICHE JOURNAL, 1997, 43 (08) :1964-1974
[8]   INTERACTION OF RADIAL AND AXIAL-DISPERSION IN LIQUID-CHROMATOGRAPHY IN RELATION TO INFINITE DIAMETER EFFECT [J].
KNOX, JH ;
LAIRD, GR ;
RAVEN, PA .
JOURNAL OF CHROMATOGRAPHY, 1976, 122 (JUL7) :129-145
[9]   Refining the scale-up of chromatographic separations [J].
Lode, FG ;
Rosenfeld, A ;
Yuan, QS ;
Root, TW ;
Lightfoot, EN .
JOURNAL OF CHROMATOGRAPHY A, 1998, 796 (01) :3-14
[10]   Visualization of solute migration in liquid chromatography columns [J].
Shalliker, RA ;
Broyles, BS ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (01) :1-13