Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: A prospective randomized trial

被引:93
作者
Thordarson, DB [1 ]
Samuelson, M [1 ]
Shepherd, LE [1 ]
Merkle, PF [1 ]
Lee, J [1 ]
机构
[1] Univ So Calif, Dept Orthopaed, Los Angeles, CA 90089 USA
关键词
D O I
10.1177/107110070102200411
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Thirty-two patients who had pronation-lateral rotation (PLR) fractures occurring four centimeters or more proximal to the ankle joint or lower if the talus was displaced greater than one centimeter laterally were enrolled in this study. Seventeen patients were randomized to fibular plate fixation with a 4.5 ml polylactic acid (PLA) bioabsorbable syndesmotic screw, and fifteen patients randomized to fibular plate fixation with a 4.5 mm stainless steel syndesmotic screw. All thirty-two patients had uncomplicated healing of their fibular fracture without loss of reduction. There was neither evidence of osteolysis nor sterile effusion in the patients who were treated with the PLA screw. There were no wound complications in either group. No difference in range of motion or subjective complaints was noted in either group. Use of the PLA syndesmotic screw at short-term follow-up was well tolerated and avoided the need for subsequent screw removal.
引用
收藏
页码:335 / 338
页数:4
相关论文
共 17 条
[1]
MECHANICAL CONSIDERATIONS FOR THE SYNDESMOSIS SCREW - A CADAVER STUDY [J].
BODEN, SD ;
LABROPOULOS, PA ;
MCCOWIN, P ;
LESTINI, WF ;
HURWITZ, SR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (10) :1548-1555
[2]
BOSTMAN O, 1990, INT ORTHOP, V14, P1
[3]
FOREIGN-BODY REACTIONS TO POLYGLYCOLIDE SCREWS - OBSERVATIONS IN 24/216 MALLEOLAR FRACTURE CASES [J].
BOSTMAN, O ;
PARTIO, E ;
HIRVENSALO, E ;
ROKKANEN, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (02) :173-176
[5]
ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[6]
FIXATION WITH BIOABSORBABLE SCREWS FOR THE TREATMENT OF FRACTURES OF THE ANKLE [J].
BUCHOLZ, RW ;
HENRY, S ;
HENLEY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) :319-324
[7]
CHEN E, 1992, T ORS 38 M, P87
[8]
MECHANICAL-PROPERTIES OF BIODEGRADABLE POLYMERS AND COMPOSITES PROPOSED FOR INTERNAL-FIXATION OF BONE [J].
DANIELS, AU ;
CHANG, MKO ;
ANDRIANO, KP ;
HELLER, J .
JOURNAL OF APPLIED BIOMATERIALS, 1990, 1 (01) :57-78
[9]
SURGICAL-TREATMENT OF FRACTURE-DISLOCATIONS OF THE ANKLE JOINT WITH BIODEGRADABLE IMPLANTS - A PROSPECTIVE RANDOMIZED STUDY [J].
DIJKEMA, ARA ;
VANDERELST, M ;
BREEDERVELD, RS ;
VERSPUI, G ;
PATKA, P ;
HAARMAN, HJTM .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 34 (01) :82-84
[10]
CHEVRON OSTEOTOMY FIXED WITH ABSORBABLE POLYGLYCOLIDE PINS [J].
HIRVENSALO, E ;
BOSTMAN, O ;
TORMALA, P ;
VAINIONPAA, S ;
ROKKANEN, P .
FOOT & ANKLE, 1991, 11 (04) :212-218