Trends and challenges in biochemical sensors for clinical and environmental monitoring

被引:94
作者
Andreescu, S [1 ]
Sadik, OA [1 ]
机构
[1] SUNY Binghamton, Dept Chem, Adv Sensor & Threat Detect Lab, Binghamton, NY 13902 USA
关键词
D O I
10.1351/pac200476040861
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Biochemical sensors have emerged as a dynamic technique for qualitative and quantitative analysis of different analytes in clinical diagnosis, environmental monitoring, and food and process control. The need for a low-cost, reliable, ultra-sensitive, and rapid sensor continues to grow as the complexity of application areas increases. New biosensing techniques are emerging due to the need for shorter sample preparation protocols. Such novel biosensor designs make field and bed-site clinical testing simpler with substantial decrease in costs per sample throughputs. In this paper, we will review the recent trends and challenges in clinical and environmental biosensors. The review will focus on immunological, nucleic acid, and cell-based clinical and biological sensors. Special emphasis will be placed on the approaches used for immobilization or biological reagents and low-cost electrochemical biosensors. The promising biosensors for rapid diagnosis of cancer or HIV are also discussed.
引用
收藏
页码:861 / 878
页数:18
相关论文
共 138 条
  • [21] Scanning electrochemical microscopy of living cells.: 3.: Rhodobacter sphaeroides
    Cai, CX
    Liu, B
    Mirkin, MV
    Frank, HA
    Rusling, JF
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (01) : 114 - 119
  • [22] Cavic BA, 1997, FARADAY DISCUSS, V107, P159
  • [23] Mediated biosensors
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) : 441 - 456
  • [24] Biosensors: recent advances
    Collings, AF
    Caruso, F
    [J]. REPORTS ON PROGRESS IN PHYSICS, 1997, 60 (11) : 1397 - 1445
  • [25] Poly(pyrrole-biotin): a new polymer for biomolecule grafting on electrode surfaces
    Cosnier, S
    Lepellec, A
    [J]. ELECTROCHIMICA ACTA, 1999, 44 (11) : 1833 - 1836
  • [26] Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
    Cosnier, S
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) : 443 - 456
  • [27] Microbial biosensors
    D'Souza, SF
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (06) : 337 - 353
  • [28] Review of analytical methods for the determination of estrogens and progestogens in waste waters
    De López Aida M.J.
    Barceló D.
    [J]. Fresenius' Journal of Analytical Chemistry, 2001, 371 (4): : 437 - 447
  • [29] Dong Shaojun, 2002, J Biotechnol, V82, P303, DOI 10.1016/S1389-0352(01)00048-4
  • [30] Characteristics of the glucose oxidase at different surfaces
    Dong, XD
    Lu, JT
    Cha, CS
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (01): : 63 - 69