High peak capacity separation of peptides through the serial connection of LC shell-packed columns

被引:29
作者
Donato, Paola [2 ]
Dugo, Paola [1 ]
Cacciola, Francesco [2 ]
Dugo, Giovanni [2 ]
Mondello, Luigi [2 ]
机构
[1] Univ Messina, Facolta Sci, Dipartimento Sci Alimenti & Ambiente, I-98166 Messina, Italy
[2] Univ Messina, Facolta Farm, Dipartimento Farmacochim, I-98166 Messina, Italy
关键词
Coupled columns; Fused-core (TM) technology; High efficiency; High temperature; HSA; LIQUID-CHROMATOGRAPHY; ELEVATED-TEMPERATURE; SUPERHEATED WATER; PERFORMANCE; EFFICIENCY; PARTICLES;
D O I
10.1002/jssc.200800639
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High peak Capacity was obtained for the separation of a HSA tryptic digest through the serial connection Of three LC columns packed with shell material (C18, 15 cm x 4.6 mm, 2.7 mu m particle size). A major benefit of these particles, consisting of a 1.7 mu m solid core and a 0.5 mu m porous shell. is the small diffusion path, which reduces axial dispersion of solutes and minimizes peak broadening allowing lot higher resolving power to be obtained. Increase ill the temperature decreases the viscosity and the backpressure oil the columns and in this way allowed to couple multiple columns. Single and multicolumn systems were first evaluated for the separation of a standard sample mixture in the isocratic mode; afterwards three columns could be coupled at 60 C. generating more than 90000 effective plates (200000 plates/meter) for the separation of HSA ill gradient mode oil I Conventional HPLC instrument. Peak capacity ratios were found in good accordance with the theoretical gain in resolution, i.e values of 1.37 and 1.67 were measured, when doubling and tripling the length of stationary phases, respectively (the highest measured peak capacity on three coupled columns was 367).
引用
收藏
页码:1129 / 1136
页数:8
相关论文
共 26 条
[1]  
[Anonymous], REPORTER EUROPE SUPE
[2]   Kinetic plot method as a tool to design coupled column systems producing 100,000 theoretical plates in the shortest possible time [J].
Cabooter, Deirdre ;
Lestremau, Francois ;
Lynen, Frederic ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) :23-34
[3]  
Carmen P. E., 1937, AIChE, V15, P150, DOI DOI 10.1016/S0263-8762(97)80003-2
[4]   Mass-transfer kinetics in a shell packing material for chromatography [J].
Cavazzini, Alberto ;
Gritti, Fabrice ;
Kaczmarski, Krzysztof ;
Marchetti, Nicola ;
Guiochon, Georges .
ANALYTICAL CHEMISTRY, 2007, 79 (15) :5972-5979
[5]   ROLE OF THE TEMPERATURE IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PYROCARBON-CONTAINING ADSORBENTS [J].
COLIN, H ;
DIEZMASA, JC ;
GUIOCHON, G ;
CZAJKOWSKA, T ;
MIEDZIAK, I .
JOURNAL OF CHROMATOGRAPHY, 1978, 167 (DEC) :41-65
[6]   Fused-core particle technology as an alternative to sub-2-αm particles to achieve high separation efficiency with low backpressure [J].
Cunliffe, Jennifer M. ;
Maloney, Todd D. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (18) :3104-3109
[7]  
David F, 2007, LC GC EUR, V20, P154
[8]   Superheated water as chromatographic eluent for parabens separation on octadecyl coated zirconia stationary phase [J].
Dugo, Paola ;
Buonasera, Katia ;
Crupi, Maria Lucia ;
Cacciola, Francesco ;
Dugo, Giovanni ;
Mondello, Luigi .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (08) :1125-1130
[9]   A column capacity study of single, serial, and parallel linked rod monolithic high performance liquid chromatography columns [J].
Gray, MJ ;
Slonecker, PJ ;
Dennis, G ;
Shalliker, RA .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1096 (1-2) :92-100
[10]   High-temperature liquid chromatography [J].
Greibrokk, T ;
Andersen, T .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :743-755