A column capacity study of single, serial, and parallel linked rod monolithic high performance liquid chromatography columns

被引:20
作者
Gray, MJ
Slonecker, PJ
Dennis, G
Shalliker, RA
机构
[1] Cincinnati Innovat Concept Ctr, Cognis Corp, Cincinnati, OH 45232 USA
[2] Univ Western Sydney, Nanoscale Org & Dynam Grp, Parramatta, NSW 1797, Australia
关键词
column capacity; monolithic; HPLC; multidimensional separational; serial linked monolithic; parallel linked monolithic; preparative HPLC; load capacity; peak capacity; volume load capacity; monolithic channels rod monolithic HPLC columns;
D O I
10.1016/j.chroma.2005.06.091
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The loading capacity of rod monolithic C18 columns was found to be sensitive to the injection volume, but essentially insensitive to the mass loading for a separation of oligostyrenes. When rod monoliths were coupled in series the injection volume loading increased, as too did the resolution of the oligomers, but at the expense of separation time. The volume load capacity of these serially connected monoliths was, however, not directly proportional to the number of columns connected. The volume load capacity was, however, directly proportional to the number of columns when the monoliths were connected in parallel and the flow stream split between each of the monolithic channels. When the number of monoliths in each channel equaled the number of monoliths that were connected in a single channel serial system the peak capacity and retention time was equivalent for both systems, but the volume load capacity of the parallel system was twice that of the serial connection each time the number of channels doubled. The results of this study indicate that parallel connection of rod monolithic columns may be useful for preparative scale and multidimensional separations where it is important that the volume load capacity is high. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 11 条
[1]   Separation of oligostyrene isomers in a complex mixture using two-dimensional heart-cutting reversed-phased liquid chromatography [J].
Gray, MJ ;
Dennis, GR ;
Slonecker, PJ ;
Shalliker, RA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1028 (02) :247-257
[2]   Comprehensive coupled reversed-phase reversed-phase separations of a complex isomeric mixture [J].
Gray, MJ ;
Sweeney, AP ;
Dennis, GR ;
Slonecker, PJ ;
Shalliker, RA .
ANALYST, 2003, 128 (06) :598-604
[3]   Repeatability and reproducibility of retention data and band profiles on six batches of monolithic columns [J].
Kele, M ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :19-49
[4]   Comprehensive two-dimensional high-performance liquid chromatography for the separation of polycyclic aromatic hydrocarbons [J].
Murahashi, T .
ANALYST, 2003, 128 (06) :611-615
[5]  
PIERCE JR, 1980, INTRO INFORMATION TH
[6]   Construction of large volume monolithic columns [J].
Podgornik, A ;
Barut, M ;
Strancar, A ;
Josic, D ;
Koloini, T .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5693-5699
[7]  
STALLINGS W, 1997, DATA COMPUTER COMMUN
[8]  
SVEC F, 2004, LCGC, V1, P1
[9]   Monolithic silica columns for high-efficiency chromatographic separations [J].
Tanaka, N ;
Kobayashi, H ;
Ishizuka, N ;
Minakuchi, H ;
Nakanishi, K ;
Hosoya, K ;
Ikegami, T .
JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) :35-49
[10]   Isolation of the active constituents in natural materials by 'heart-cutting' isocratic reversed-phase two-dimensional liquid chromatography [J].
Wong, V ;
Shalliker, RA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1036 (01) :15-24