Accuracy of patient positioning during radiotherapy for bladder and brain tumours

被引:12
作者
Hanna, CL [1 ]
Slade, S
Mason, MD
Burnet, NG
机构
[1] Velindre Hosp NHS Trust, Cardiff CF4 7XL, S Glam, Wales
[2] Addenbrookes Hosp, Cambridge, England
关键词
planning target volume; portal beam film; radiotherapy; set-up errors;
D O I
10.1053/clon.1999.9021
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We report the results of a prospective study to quantify inaccuracies in patient set-up during routine radiotherapy for tumours of the brain and bladder, which took place as part of our departmental development. Knowledge of these inaccuracies is required to put into practice the ICRU 50 recommendations regarding clinical target volume and planning target volume. We measured inaccuracies in two dimensions by comparing portal beam films with the simulator check film. Our method used manual measurements, proved to be a very laborious technique, and demonstrated the need for portal imaging. Ninety-five brain and 97 bladder portal films from 30 brain and 30 bladder patients were examined. Displacements greater than 0.5 cm were seen in 13% of brain treatments in the supero-inferior direction and 1% in the anteroposterior direction. With bladder treatments, displacements greater than 0.75 cm were seen in 12% in the supero-inferior direction and 5% in the lateral direction. These results are consistent with other previous studies. We identified a very small systematic error in the department, which was considered to be clinically significant. These results are discussed with reference to other similar studies and the ICRU 50 recommendations.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 14 条
[1]   Reproducibility of conformal radiation therapy in localized carcinoma of the prostate without rigid immobilization [J].
Bieri, S ;
Miralbell, R ;
Nouet, P ;
Delorme, H ;
Rouzaud, M .
RADIOTHERAPY AND ONCOLOGY, 1996, 38 (03) :223-230
[2]   3-DIMENSIONAL VERIFICATION OF PATIENT PLACEMENT DURING RADIOTHERAPY USING PORTAL IMAGES [J].
BIJHOLD, J .
MEDICAL PHYSICS, 1993, 20 (02) :347-356
[3]   WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS [J].
BYHARDT, RW ;
COX, JD ;
HORNBURG, A ;
LIERMANN, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10) :881-887
[4]  
CAMPBELL M, 1993, MARXS METHOD IN CAPITAL, P135
[5]   REPRODUCIBILITY OF PATIENT POSITIONING DURING ROUTINE RADIOTHERAPY, AS ASSESSED BY AN INTEGRATED MEGAVOLTAGE IMAGING-SYSTEM [J].
GILDERSLEVE, J ;
DEARNALEY, DP ;
EVANS, PM ;
SWINDELL, W .
RADIOTHERAPY AND ONCOLOGY, 1995, 35 (02) :151-160
[6]   Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate [J].
Hanley, J ;
Lumley, MA ;
Mageras, GS ;
Sun, J ;
Zelefsky, MJ ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :435-444
[7]  
Harris S J, 1998, Clin Oncol (R Coll Radiol), V10, P262, DOI 10.1016/S0936-6555(98)80014-9
[8]   Accuracy of pelvic radiotherapy: Prospective analysis of 90 patients in a randomised trial of blocked versus standard radiotherapy [J].
Huddart, RA ;
Nahum, A ;
Neal, A ;
McLean, M ;
Dearnaley, DP ;
Law, M ;
Dyer, J ;
Tait, D .
RADIOTHERAPY AND ONCOLOGY, 1996, 39 (01) :19-29
[9]  
International Commission in Radiation Units and Measurements, 1993, 50 ICRU
[10]  
Kutcher, 1995, Semin Radiat Oncol, V5, P134, DOI 10.1016/S1053-4296(95)80006-9