Amperometric determination of underivatized amino acids at a nickel-modified gold electrode by anion-exchange chromatography

被引:47
作者
Casella, IC [1 ]
Gatta, M [1 ]
Cataldi, TRI [1 ]
机构
[1] Univ Basilicata, Dipartimento Chim, I-85100 Potenza, Italy
关键词
amperometric detection; LC; cheese; food analysis; amino acids;
D O I
10.1016/S0021-9673(00)00274-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A nickel-based composite electrode obtained by anodic electrodeposition of nickel (III) oxyhydroxide film on the gold electrode substrate was characterized as an amperometric sensor and successfully applied to the determination of underivatised amino acids in flow-through systems. The electrodeposition of nickel oxyhydroxide films was obtained by cycling a gold electrode between 0.0 V and +1.0 V vs. a saturated calomel electrode in a 80 mu M Ni2+ solution buffered at pH 10 with NaHCO3/Na2CO3. The resulting Au-Ni composite electrode exhibits good stability in alkaline medium and can be used as an amperometric sensor of underivatised amino acids at a fixed applied potential (+0.55 V vs. Ag/AgCl). The detection limits (S/N=3) for all investigated compounds ranged between 5 and 30 pmol injected, while the linear ranges spanned over two or three orders of magnitude. The contents of several free amino acids in two sample cheeses from different brands were evaluated by calibration graphs. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:57 / 67
页数:11
相关论文
共 28 条
[1]   THE SEPARATION OF 24 OPA-AA OF NATURAL ORIGIN AND QUANTITATIVE-ANALYSIS OF TYROSINE BY MEANS OF HPLC [J].
ABECASSIS, J ;
DAVIDETEVE, C ;
SOUN, A .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1985, 8 (01) :135-153
[2]   SIMPLE, RAPID, AND HIGHLY EFFICIENT SEPARATION OF AMINO-ACID PHENYLTHIOHYDANTOINS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BLACK, SD ;
COON, MJ .
ANALYTICAL BIOCHEMISTRY, 1982, 121 (02) :281-285
[3]   AN INSITU WEIGHING STUDY OF THE MECHANISM FOR THE FORMATION OF THE ADSORBED OXYGEN MONOLAYER AT A GOLD ELECTRODE [J].
BRUCKENSTEIN, S ;
SHAY, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 188 (1-2) :131-136
[4]   Voltammetric and XPS investigations of nickel hydroxide electrochemically dispersed on gold surface electrodes [J].
Casella, IG ;
Guascito, MR ;
Sannazzaro, MG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 462 (02) :202-210
[5]   STUDY OF A NICKEL-CATALYZED GLASSY-CARBON ELECTRODE FOR DETECTION OF CARBOHYDRATES IN LIQUID-CHROMATOGRAPHY AND FLOW-INJECTION ANALYSIS [J].
CASELLA, IG ;
DEIMONI, F ;
CATALDI, TRI .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :117-125
[6]   Electrocatalysis and amperometric detection of alditols and sugars at a gold-nickel composite electrode in anion-exchange chromatography [J].
Casella, IG ;
Guascito, MR ;
Cataldi, TRI .
ANALYTICA CHIMICA ACTA, 1999, 398 (2-3) :153-160
[7]   Copper dispersed into polyaniline films as an amperometric sensor in alkaline solutions of amino acids and polyhydric compounds [J].
Casella, IG ;
Cataldi, TRI ;
Guerrieri, A ;
Desimoni, E .
ANALYTICA CHIMICA ACTA, 1996, 335 (03) :217-225
[8]  
Casella IG, 1998, ELECTROANAL, V10, P1005, DOI 10.1002/(SICI)1521-4109(199810)10:15<1005::AID-ELAN1005>3.0.CO
[9]  
2-R
[10]   ELECTROCATALYTIC OXIDATION AND LIQUID-CHROMATOGRAPHIC DETECTION OF ALIPHATIC-ALCOHOLS AT A NICKEL-BASED GLASSY-CARBON MODIFIED ELECTRODE [J].
CASELLA, IG ;
CATALDI, TRI ;
SALVI, AM ;
DESIMONI, E .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3143-3150