Proponents of navigated hip arthroplasty have suggested that it may increase the precision of acetabular component placement. We conducted a systematic review and meta-analysis to evaluate the validity of this theory. We searched, in duplicate, MEDLINE, EMBASE and the Cochrane Central Register of Controlled Trials for randomised trials comparing the use of computer navigation with the freehand technique for acetabular cup placement within the desired alignment. We assessed the methodological quality of the studies and abstracted the relevant data. Tests of heterogeneity and publication bias were performed. From the three studies included, there was no evidence of heterogeneity between studies. A total of 250 patients were entered into the analysis. The beneficial odds ratio for the number of outliers was 0.285 (95% confidence interval [CI]: 0.143 to 0.569; p < 0.001). We conclude that navigation in hip arthroplasty improves the precision of acetabular cup placement by decreasing the number of outliers from the desired alignment.
引用
收藏
页码:593 / 597
页数:5
相关论文
共 17 条
[1]
Effects of acetabular abduction on cup wear rates in total hip arthroplasty [J].
Del Schutte, H ;
Lipman, AJ ;
Bannar, SM ;
Livermore, JT ;
Ilstrup, D ;
Morrey, BF .
JOURNAL OF ARTHROPLASTY, 1998, 13 (06) :621-626
[2]
Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[3]
Mini-incision technique for total hip arthroplasty with navigation [J].
DiGioia, AM ;
Plakseychuk, AY ;
Levison, TJ ;
Jaramaz, B .
JOURNAL OF ARTHROPLASTY, 2003, 18 (02) :123-128
[4]
Bias in meta-analysis detected by a simple, graphical test [J].
Egger, M ;
Smith, GD ;
Schneider, M ;
Minder, C .
BMJ-BRITISH MEDICAL JOURNAL, 1997, 315 (7109) :629-634
[5]
Comparison of conventional versus computer-navigated acetabular component insertion [J].
Haaker, Rolf G. A. ;
Tiedjen, Kai ;
Ottersbach, Andreas ;
Rubenthaler, Frank ;
Stockheim, Marthin ;
Stiehl, James B. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (02) :151-159
[6]
Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement [J].
Jolles, BM ;
Genoud, P ;
Hoffmeyer, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :174-179
[7]
Imageless navigation for insertion of the acetabular component in total hip arthroplasty -: Is it as accurate as CT-based navigation? [J].
Kalteis, T ;
Handel, A ;
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :163-167
[8]
Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration [J].
Kennedy, JG ;
Rogers, WB ;
Soffe, KE ;
Sullivan, RJ ;
Griffen, DG ;
Sheehan, LJ .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :530-534
[9]
Leenders T, 2002, Comput Aided Surg, V7, P99, DOI 10.1002/igs.10033
[10]
DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220