Interlaboratory evaluation of injection techniques for triglyceride analysis of cocoa butter by capillary gas chromatography

被引:25
作者
Buchgraber, M [1 ]
Ulberth, F [1 ]
Anklam, E [1 ]
机构
[1] European Commiss, DG Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
关键词
interlaboratory studies; food analysis; injection methods; triglycerides;
D O I
10.1016/j.chroma.2004.03.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As part of two international collaborative studies, in which 14 laboratories applied capillary GLC to determine the triglyceride (TG) profile of cocoa butter, the performance of different sample introduction techniques, i.e. cold on-column injection (00), split injection and programmed-temperature vapouriser (PTV) injection, was compared. In both studies, the participants did not apply a uniform GLC procedure. Synthetic mixtures of triglycerides were chosen to permit an accurate determination of detector response factors. No statistically significant difference was found between the mean values obtained by different injection modes. The 00, generally recommended as best practice, did not give superior results than the PTV or the split injection techniques. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 21 条
[11]   ANALYSIS OF TRIGLYCERIDES BY CAPILLARY GAS-CHROMATOGRAPHY WITH PROGRAMMED-TEMPERATURE INJECTION [J].
HINSHAW, JV ;
SEFEROVIC, W .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (12) :731-736
[12]   PROGRAMMED-TEMPERATURE SPLIT-SPLITLESS INJECTION OF TRIGLYCERIDES - COMPARISON TO COLD ON-COLUMN INJECTION [J].
HINSHAW, JV ;
SEFEROVIC, W .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (02) :69-72
[14]   QUANTITATIVE CAPILLARY GAS-LIQUID-CHROMATOGRAPHY OF TRIGLYCERIDES ON A FUSED-SILICA COLUMN WITH A CHEMICALLY BONDED STATIONARY PHASE [J].
MARES, P ;
HUSEK, P .
JOURNAL OF CHROMATOGRAPHY, 1985, 350 (01) :87-103
[15]   Triacylglycerol mixture for testing capillary columns for high-temperature gas chromatography [J].
Mayer, BX ;
Lorbeer, E .
JOURNAL OF CHROMATOGRAPHY A, 1997, 758 (02) :235-242
[16]  
OEZANKA T, 1991, J CHROMATOGR, V542, P145
[17]   AUTOMATIC INJECTION IN HIGH-RESOLUTION GAS-CHROMATOGRAPHY - A PROGRAMMED TEMPERATURE VAPORIZER AS A GENERAL-PURPOSE INJECTION SYSTEM [J].
POY, F ;
VISANI, S ;
TERROSI, F .
JOURNAL OF CHROMATOGRAPHY, 1981, 217 (NOV) :81-90
[18]  
REGUEIRO JAG, 1994, HRC-J HIGH RES CHROM, V17, P180
[19]   GAS-CHROMATOGRAPHY OF TRIACYLGLYCEROLS IN PALM OIL FRACTIONS WITH MEDIUM-POLARITY WIDE-BORE COLUMNS [J].
SASSANO, GJ ;
JEFFREY, BSJ .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1993, 70 (11) :1111-1114
[20]   HIGH OVEN TEMPERATURE - COLD ON-COLUMN INJECTION FOR THE AUTOMATED CGC ANALYSIS OF HIGH-MOLECULAR-WEIGHT COMPOUNDS SUCH AS TRIGLYCERIDES [J].
TERMONIA, M ;
MUNARI, F ;
SANDRA, P .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :263-268