A flow-batch internal standard procedure for iron determination in hydrated ethanol fuel by flame atomic absorption spectrometry

被引:31
作者
da Silva, Jose Edson
da Silva, Fabio Andre
Pimentel, M. Fernanda
Honorato, Ricardo Saldanha
da Silva, Valdinete Lins
Montenegro, B. S. M.
Araujo, Alberto N.
机构
[1] UFPE, Dept Engn Quim, BR-50740521 Recife, PE, Brazil
[2] UFPE, Dept Quim Fundamental, BR-50740521 Recife, PE, Brazil
[3] SR DPF PE, Dept Policia Fed, Recife, PE, Brazil
[4] UP, Fac Farm, REQUIMTE, Dept Quim Fis, Oporto, Portugal
关键词
hydrated ethanol fuel; iron; internal standard calibration; flame atomic absorption spectrometry;
D O I
10.1016/j.talanta.2005.12.057
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-batch manifold coupled to a flame atomic absorption spectrometer was evaluated to assess the iron content by the internal standard method in hydrated ethanol used as fuel in automotive industry. For this assessment official methods require calibration procedures with matrix matching, making it difficult to obtain accurate results for samples adulterated by the addition of water. Nickel was selected as the internal standard since it is usually absent in samples and because it requires similar conditions of atomization. After procedure optimization, which requires about 4.25 mL of sample and standard per measurement, it was possible to get linear analytical response for iron concentrations between 0.12 and 1.40 mg L-1 and a detection limit of 0.04 mg L-1. Eighteen samples were collected randomly from fuel stations in Pernambuco (Brazil) and iron concentration was determined using the proposed procedure. Comparison of results obtained (0.20-1.50 mg L-1) showed a mean standard error of 3.9%, with 3.8% and 2.3% calculated for the mean variation coefficients of the proposed method and the reference procedure, respectively. For adulterated samples (0.12-0.64 mg L-1), the mean standard error was 4.8% when compared with the standard addition method. These results allowed concluding that the proposed procedure is adequate to accomplish the determination of iron in ethanol fuel in a large scale basis with a sampling rate of about 10 h(-1). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:522 / 526
页数:5
相关论文
共 22 条
[1]   Improving isotope ratio precision in inductively coupled plasma quadrupole mass spectrometry by common analyte internal standardization [J].
Al-Ammar, AS ;
Barnes, RM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (04) :327-332
[2]   Correction for non-spectroscopic matrix effects in inductively coupled plasma-mass spectrometry by common analyte internal standardization [J].
Al-Ammar, AS ;
Gupta, RK ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (13) :1849-1860
[3]   Determination of cadmium and lead in table salt by sequential multi-element flame atomic absorption spectrometry [J].
Amorim, FAC ;
Ferreira, SLC .
TALANTA, 2005, 65 (04) :960-964
[4]  
*ASS BRAS NORM TEC, 1990, 11331 ABNT NBR
[5]  
ATSUYA I, 1991, PURE APPL CHEM, V63, P1121
[6]   MULTIPLE ELEMENT ATOMIC ABSORPTION ANALYSIS [J].
BUTLER, LRP ;
STRASHEIM, A .
SPECTROCHIMICA ACTA, 1965, 21 (07) :1207-+
[7]   SIMPLE ANALYSIS OF AMOXICILLIN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INTERNAL STANDARDIZATION AND ULTRAVIOLET DETECTION [J].
CHARLES, B ;
CHULAVATNATOL, S .
BIOMEDICAL CHROMATOGRAPHY, 1993, 7 (04) :204-207
[8]   QUANTITATION OF BIOLOGICAL RETINOIDS BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY - PRIMARY INTERNAL STANDARDIZATION USING TRITIATED RETINOIDS [J].
CULLUM, ME ;
ZILE, MH .
ANALYTICAL BIOCHEMISTRY, 1986, 153 (01) :23-32
[9]   Simultaneous determination of As, Hg, Sb, Se and Sn in sediments by slurry sampling axial view inductively coupled plasma optical emission spectrometry using on-line chemical vapor generation with internal standardization [J].
dos Santos, EJ ;
Herrmann, AB ;
Frescura, VLA ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (06) :538-543
[10]   DETERMINATION OF MAJOR CONSTITUENTS BY ATOMIC ABSORPTION SPECTROMETRY [J].
FELDMAN, FJ ;
BLASI, JA ;
SMITH, SB .
ANALYTICAL CHEMISTRY, 1969, 41 (08) :1095-&