Price of isotropy in multidetector CT

被引:52
作者
Dalrymple, Neal C. [1 ]
Prasad, Srinivasa R. [1 ]
El-Merhi, Fadi M. [1 ]
Chintapalli, Kedar N. [1 ]
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Radiol, San Antonio, TX 78229 USA
关键词
D O I
10.1148/rg.271065037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent advances in multidetector computed tomography (CT) have made isotropic data acquisition feasible for nearly every application. The benefits of routine use of isotropic data for image display and interpretation have been described in the literature and at educational conferences. However, there is usually a trade-off in the form of an increased radiation dose to the patient. The parameters that affect the radiation dose vary considerably in accordance with the CT scanner design, and those variations determine the cost in dose increase relative to the voxel size. The detector configuration and beam collimation ( narrow or wide) used for a particular acquisition also affect the voxel size and the relationship between spatial resolution and the radiation dose. By closely comparing the quality of multidetector CT images obtained with different detector configurations on scanners with four, 16, 40, and 64 channels and the estimated radiation exposure incurred with each option, radiologists may achieve an understanding of the relationship between radiation dose and voxel size. This understanding, in turn, may help balance the need for diagnostic image quality against the concern for patient safety.
引用
收藏
页码:49 / U4
页数:15
相关论文
共 18 条
[1]   Optimization of MDCT of the wrist to achieve diagnostic image quality with minimum radiation exposure [J].
Bonel, HM ;
Jäger, L ;
Frei, KA ;
Galiano, S ;
Srivastav, SK ;
Flohr, T ;
Reiser, MF ;
Dinkel, HP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (03) :647-654
[2]   16-MDCT of the posttraumatic pediatric elbow: Optimum parameters and associated radiation dose [J].
Chapman, VM ;
Kalra, M ;
Halpern, E ;
Grottkau, B ;
Albright, M ;
Jaramillo, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (02) :516-521
[3]   Informatics in radiology (infoRAD) -: Introduction to the language of three-dimensional imaging with multidetector CT [J].
Dalrymple, NC ;
Prasad, SR ;
Freckleton, MW ;
Chintapalli, KN .
RADIOGRAPHICS, 2005, 25 (05) :1409-1428
[4]   Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[5]   Dose and image quality in CT [J].
Huda, W .
PEDIATRIC RADIOLOGY, 2002, 32 (10) :709-713
[6]   PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING [J].
KALENDER, WA ;
POLACIN, A .
MEDICAL PHYSICS, 1991, 18 (05) :910-915
[7]   Sixteen-detector row CT of abdomen and pelvis: Study for optimization of Z-axis modulation technique performed in 153 patients [J].
Kalra, MK ;
Maher, MM ;
Kamath, RS ;
Horiuchi, T ;
Toth, TL ;
Halpern, EF ;
Saini, S .
RADIOLOGY, 2004, 233 (01) :241-249
[8]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[9]   Four- and eight-channel aortoiliac CT angiography: A comparative study [J].
Karcaaltincaba, M ;
Foley, D .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (02) :169-172
[10]  
LEWIS M, 2004, IMPACT TECHNOLOGY UP, P1