Elastomer-glass micropump employing active throttles

被引:16
作者
Johnston, ID [1 ]
Davis, JB
Richter, R
Herbert, GI
Tracey, MC
机构
[1] Univ Hertfordshire, Sci & Technol Res Ctr, Hatfield AL10 9AB, Herts, England
[2] Tech Univ Dresden, Inst Feinwerktech & Elekt Design, D-8027 Dresden, Germany
关键词
D O I
10.1039/b407760c
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
We report a reciprocating microfluidic pump, the Micro Throttle Pump (MTP), constructed in a relatively uncomplicated manner from glass and microstructured poly(dimethylsiloxane) (PDMS). Unconventionally, the MTP employs throttling of fluid flow as distinct from fully-closing valve structures. Accordingly, this technique offers the prospect of solid-phase suspension tolerance. The reported MTP employs piezoelectrically (PZT) actuated deformation of flow constrictions (throttles) fabricated from PDMS at the two ports of a central, PZT actuated pump chamber. By appropriate time-sequencing of the individual PZTs' actuation, pumping can be induced in either direction. PDMS' elasticity further facilitates throttle operation by virtue of allowing significant PZT flexure that is substantially independent of the underlying PDMS microstructure. In contrast, in a rigid substrate such as silicon, deformation is constrained to where underlying microstructured cavities exist and this restricts design options. We describe the construction and performance of a prototype MTP capable of pumping 300 mul min(-1) or alternatively generating a back-pressure of 5.5 kPa. Preliminary modelling of MTP operation is also presented.
引用
收藏
页码:829 / 834
页数:6
相关论文
共 23 条
[1]
A valve-less diffuser micropump for microfluidic analytical systems [J].
Andersson, H ;
van der Wijngaart, W ;
Nilsson, P ;
Enoksson, P ;
Stemme, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (03) :259-265
[2]
UV/ozone modification of poly(dimethylsiloxane) microfluidic channels [J].
Berdichevsky, Y ;
Khandurina, J ;
Guttman, A ;
Lo, YH .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 97 (2-3) :402-408
[3]
Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[4]
Surface modification of Sylgard-184 poly(dimethyl siloxane) networks by ultraviolet and ultraviolet/ozone treatment [J].
Efimenko, K ;
Wallace, WE ;
Genzer, J .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2002, 254 (02) :306-315
[5]
FORSTER K, 1995, P ASME FLUIDS ENG DI, P39
[6]
Microfabricated electrolysis pump system for isolating rare cells in blood [J].
Furdui, VI ;
Kariuki, JK ;
Harrison, DJ .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (04) :S164-S170
[7]
Monolithic membrane valves and diaphragm pumps for practical large-scale integration into glass microfluidic devices [J].
Grover, WH ;
Skelley, AM ;
Liu, CN ;
Lagally, ET ;
Mathies, RA .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (03) :315-323
[8]
Hydrophobicity recovery of polydimethylsiloxane after exposure to corona discharges [J].
Hillborg, H ;
Gedde, UW .
POLYMER, 1998, 39 (10) :1991-1998
[9]
Design and fabrication of integrated passive valves and pumps for flexible polymer 3-dimensional microfluidic systems [J].
Jeon, NL ;
Chiu, DT ;
Wargo, CJ ;
Wu, HK ;
Choi, IS ;
Anderson, JR ;
Whitesides, GM .
BIOMEDICAL MICRODEVICES, 2002, 4 (02) :117-121
[10]
Hydrophobic recovery of polydimethylsiloxane elastomer exposed to partial electrical discharge [J].
Kim, J ;
Chaudhury, MK ;
Owen, MJ .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2000, 226 (02) :231-236