Fluorescence coherence tomography

被引:17
作者
Bilenca, A.
Ozcan, A.
Bouma, B.
Tearney, G.
机构
[1] Harvard Univ, Sch Med, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Wellman Ctr Photomed, Boston, MA 02114 USA
关键词
D O I
10.1364/OE.14.007134
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper, we introduce a new form of cross-sectional, coherence-gated fluorescence imaging, which we term 'spectral-domain fluorescence coherence tomography' (SD-FCT). SD-FCT is accomplished by spectrally detecting self-interference of the spontaneous emission of fluorophores located along the axial (depth) dimension of the sample. We have built a first generation SD-FCT system that utilizes two opposing low numerical-aperture objective lenses in an interferometer and an imaging spectrometer for detecting self-interference of fluorescence emitted from a sample. Here, in proof-of-principle experiments we demonstrate cross-sectional profiling of layered fluorescence phantoms. Narrow (a few micrometers FWHM) axial point-spread functions, large ranging depths (a few hundreds of micrometers) and wide fields of view (> 1 mm) were measured. Initial results suggest that SD-FCT may be a viable tool for the investigation of semi-transparent and selectively labeled fluorescent samples. (c) 2006 Optical Society of America
引用
收藏
页码:7134 / 7143
页数:10
相关论文
共 17 条
[1]   Multicanonical Monte-Carlo simulations of light propagation in biological media [J].
Bilenca, A ;
Desjardins, A ;
Bouma, BE ;
Tearney, GJ .
OPTICS EXPRESS, 2005, 13 (24) :9822-9833
[2]   Spectral resolution and sampling issues in Fourier-transform spectral interferometry [J].
Dorrer, C ;
Belabas, N ;
Likforman, JP ;
Joffre, M .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2000, 17 (10) :1795-1802
[3]   LOCALIZATION OF SPONTANEOUS EMISSION IN FRONT OF A MIRROR [J].
DRABE, KE ;
CNOSSEN, G ;
WIERSMA, DA .
OPTICS COMMUNICATIONS, 1989, 73 (02) :91-95
[4]  
Drexhage K. H., 1974, PROGR OPTICS, P163, DOI DOI 10.1016/S0079-6638(08)70266-X
[5]  
Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI [10.1088/0034-4885/66/2/204, 10.2184/lsj.31.635]
[6]   Parallel Fourier domain optical coherence tomography for in vivo measurement of the human eye [J].
Grajciar, B ;
Pircher, M ;
Fercher, AF ;
Leitgeb, RA .
OPTICS EXPRESS, 2005, 13 (04) :1131-1137
[7]  
GUSTAFSSON MGL, 1995, P SOC PHOTO-OPT INS, V2412, P147, DOI 10.1117/12.205334
[8]   PROPERTIES OF A 4PI CONFOCAL FLUORESCENCE MICROSCOPE [J].
HELL, S ;
STELZER, EHK .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1992, 9 (12) :2159-2166
[9]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[10]   Optical sectioning deep inside live embryos by selective plane illumination microscopy [J].
Huisken, J ;
Swoger, J ;
Del Bene, F ;
Wittbrodt, J ;
Stelzer, EHK .
SCIENCE, 2004, 305 (5686) :1007-1009