Radiometry with synchrotron radiation

被引:13
作者
Wende, B
机构
关键词
D O I
10.1088/0026-1394/32/6/3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Electron storage rings are in use or planned for use in the extension of radiometry into ranges of higher photon energies, from the visible spectral region continuously to the x-ray region up to photon energies of at least 100 keV. The storage rings serve as broadband primary standard sources for the development of a source-based radiometry and as sources of tuneable monochromatic photon fluxes for the development of a detector-based radiometry in combination with primary standard detectors. The state of the art is briefly summarized based on results obtained at the Berlin storage ring BESSY I (maximum electron energy 850 MeV), which was optimized for radiometry from the outset. Further progress in radiometry is expected at the future storage ring BESSY II (start of operation in 1998). At this third-generation storage ring (maximum electron energy 1,9 GeV) radiation from undulators, wigglers and wavelength shifters will be used for radiometry in addition to traditional synchrotron radiation from bending magnets. Furthermore, there are prospects at BESSY II to extend radiometry into the gamma-ray range with photon energies in the MeV region by scattering laser and undulator photons at stored relativistic electrons.
引用
收藏
页码:419 / 424
页数:6
相关论文
共 26 条
[1]  
ALUFRAMBS A, 1995, METROLOGIA, V32, P571
[2]   REALIZATION OF A SPECTRAL RADIANCE SCALE IN THE 40-250-NM SPECTRAL REGION-BASED ON A TROLL-TYPE SYNCHROTRON [J].
ANEVSKY, SI ;
VERNYI, AE ;
KHROMCHENKO, VB ;
PANASYUK, VS ;
SAPRITSKY, VI .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) :573-576
[3]   DETERMINATION OF PHOTON-EMISSION PROBABILITIES OF RADIONUCLIDES USING A SI(LI) DETECTOR CALIBRATED BY THE PRIMARY STANDARD SOURCE, BESSY [J].
ARNOLD, D ;
ULM, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2) :43-48
[4]   ELECTRON STORAGE RING BESSY AS A SOURCE OF CALCULABLE SPECTRAL PHOTON FLUX IN THE X-RAY REGION [J].
ARNOLD, D ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1539-1542
[5]   THE STATION FOR DETECTOR CALIBRATION IN THE SOFT-X-RAY RANGE AT THE VEPP-2M STORAGE-RING [J].
CHKHALO, NI ;
EVSTIGNEEV, AV ;
KHOLOPOV, MA ;
LYAKH, VV ;
NIKOLENKO, AD ;
PINDYURIN, VF ;
SUBBOTIN, AN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (1-2) :440-444
[6]   MEASUREMENTS OF THE ABSOLUTE SPECTRAL SENSITIVITY OF X-RAY SEMICONDUCTOR-DETECTORS IN THE PHOTON ENERGY-RANGE OF 1.5-15 KEV USING WHITE SR BEAM OF THE VEPP-3 STORAGE-RING [J].
DOLBNYA, IP ;
MAKAROV, OA ;
MEZENTSEV, NA ;
PINDYURIN, VF ;
SUBBOTIN, AN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (1-2) :427-431
[7]  
Friedrich R, 1996, METROLOGIA, V32, P509, DOI 10.1088/0026-1394/32/6/22
[8]   RADIOMETRY AT THE NIST SURF-II STORAGE-RING FACILITY [J].
FURST, ML ;
GRAVES, RM ;
CANFIELD, LR ;
VEST, RE .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2257-2259
[9]   HIGH-CURRENT HOLLOW-CATHODE SOURCE AS A RADIANT INTENSITY STANDARD IN THE 40-125-NM WAVELENGTH RANGE [J].
HOLLANDT, J ;
KUHNE, M ;
WENDE, B .
APPLIED OPTICS, 1994, 33 (01) :68-74
[10]   DETERMINATION OF ABSOLUTE EMISSION CROSS-SECTIONS FOR ELECTRON-IMPACT-INDUCED LINE RADIATION IN THE VACUUM-ULTRAVIOLET [J].
JANS, W ;
MOBUS, B ;
KUHNE, M ;
ULM, G ;
WERNER, A ;
SCHARTNER, KH .
APPLIED OPTICS, 1995, 34 (19) :3671-3680