Perfusion and molecular diffusion-weighted MR imaging of the brain:: In vivo assessment of tissue alteration in cerebral ischemia

被引:4
作者
Flacke, S
Urbach, H
Block, W
Träber, F
Mürtz, P
Keller, E
Hartmann, A
Schild, HH
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
[2] Univ Bonn, Dept Neurol, D-53105 Bonn, Germany
关键词
diffusion-weighted imaging; perfusion imaging; stroke; brain; penumbra;
D O I
10.1007/s00726-001-0143-1
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The combined use of perfusion imaging (PI) and diffusion-weighted imaging (DWI) is opening a new window into the processes that occur during the first hours of ischemia. DWI detects changes in molecular diffusion associated with cytotoxic edema. PI characterizes the degree of regional hypoperfusion. Regions showing mismatches between DWI and PI, i.e. hypoperfused areas with normal diffusion behavior are considered potentially salvageable. We present results of 11 patients with an occlusion of the middle cerebral artery stem and spontaneous stroke evolution. Whereas the infarct was clearly visible on initial DWI and PI, surrounding tissue at risk of infarction was marked in all patients by an increased blood volume and transit time, but only in a subgroup (n = 3) where alteration were more pronounced this tissue at risk was progressively infarcted. These human DWI and PI data show alterations in the area of tissue at risk which correlates with infarct progression.
引用
收藏
页码:309 / 316
页数:8
相关论文
共 39 条
[11]  
Flacke S, 1999, ROFO-FORTSCHR RONTG, V170, P290
[12]  
Flacke S, 2000, JMRI-J MAGN RESON IM, V11, P250, DOI 10.1002/(SICI)1522-2586(200003)11:3<250::AID-JMRI3>3.0.CO
[13]  
2-O
[14]   Reliability of the National Institutes of Health Stroke Scale - Extension to non-neurologists in the context of a clinical trial [J].
Goldstein, LB ;
Samsa, GP .
STROKE, 1997, 28 (02) :307-310
[15]  
Karonen JO, 2000, J NUCL MED, V41, P788
[16]   Combined perfusion- and diffusion-weighted MR imaging in acute ischemic stroke during the 1st week: A longitudinal study [J].
Karonen, JO ;
Liu, YW ;
Vanninen, RL ;
Ostergaard, L ;
Partanen, PLK ;
Vainio, PA ;
Vanninen, EJ ;
Nuutinen, J ;
Roivainen, R ;
Soimakallio, S ;
Kuikka, IT ;
Aronen, HJ .
RADIOLOGY, 2000, 217 (03) :886-894
[17]   Systematic review of diffusion and perfusion imaging in acute ischemic stroke [J].
Keir, SL ;
Wardlaw, JM .
STROKE, 2000, 31 (11) :2723-2731
[18]   Diffusion- and perfusion-weighted magnetic resonance imaging in deep cerebral venous thrombosis [J].
Keller, E ;
Flacke, S ;
Urbach, H ;
Schild, HH .
STROKE, 1999, 30 (05) :1144-1146
[19]   A FUNCTIONAL MRI TECHNIQUE COMBINING PRINCIPLES OF ECHO-SHIFTING WITH A TRAIN OF OBSERVATIONS (PRESTO) [J].
LIU, GY ;
SOBERING, G ;
DUYN, J ;
MOONEN, CTW .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (06) :764-768
[20]   Diffusion-weighted MR imaging: Navigated multi-shot SE EPI technique for clinical use. [J].
Murtz, P ;
Flacke, S ;
Traber, F ;
Keller, E ;
Gieseke, J ;
Folkers, P ;
Schild, HH .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (06) :580-588