Direct analysis of bromide in human serum by capillary electrophoresis

被引:20
作者
Pascali, Jennifer P. [1 ]
Trettene, Maristella [1 ]
Bortolotti, Federica [1 ]
de Paoli, Giorgia [1 ]
Gottardo, Rossella [1 ]
Tagliaro, Franco [1 ]
机构
[1] Univ Hosp Politecn, Unit Forens Med, Dept Med & Publ Hlth, I-37134 Verona, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2006年 / 839卷 / 1-2期
关键词
serum bromide analysis; capillary electrophoresis; potassium bromide therapy; epilepsy;
D O I
10.1016/j.jchromb.2005.11.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The purpose of the present work was the development and validation of a simple, rapid and reliable method for direct bromide quantification in serum based on capillary electrophoresis (CE). The analysis was carried out with an automated capillary electropherograph. Analytical conditions were as follows. Capillary: uncoated fused silica, effective length 50 cm, internal diameter 50 mu m; voltage: 20 kV in reverse polarity mode; temperature: 25 degrees C; running buffer: 90 mmol/L sodium tetraborate decahydrate and 10 mmol/L NaCl, pH 9.24; detection: direct UV absorption at 200 nm; sample treatment: dilution of serum 1: 10 with the internal standard solution (2 mmol/L thiocyanate). Under the described conditions, bromide ions and internal standard were baseline separated in 7 min. No interferences from other serum components were observed. The analytical sensitivity was characterized by a LOD: 0.05 mmol/L and a LOQ of 0.1 mmol/L. Excellent linearity was verified in the range from 2.5 to 60 mmol/L [y = 0.0746x - 0.0372; R-2 = 0.9995 (x = bromide concentration; y = bromide peak area/intemal standard (I.S.) peak area)]. Quantitative imprecision in intra-day (n = 7) and day-to-day (n = 7) experiments was always within R.S.D. values < 2%. Recovery was quantitative throughout the range of linearity of the method. Clinical cases of infants undergoing potassium bromide therapy for refractory epilepsy were analyzed with results in agreement with literature data. On the basis of these considerations, capillary electrophoresis can be proposed as the method of choice for bromide analysis in serum samples, especially for therapeutic drug monitoring purposes. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2 / 5
页数:4
相关论文
共 16 条
[1]   Selective determination of chloride and bromide ions in serum by cyclic voltammetry [J].
Arai, K ;
Kusu, F ;
Noguchi, N ;
Takamura, K ;
Osawa, H .
ANALYTICAL BIOCHEMISTRY, 1996, 240 (01) :109-113
[2]   SIMULTANEOUS DETERMINATION FROM INORGANIC ANIONS IN HUMAN FLUIDS - A NEW METHOD IN PEDIATRIC LABORATORY - RESULTS FROM A PILOT-STUDY [J].
BOHN, I ;
NIESSEN, KH ;
REINEKE, F ;
TEUFEL, M .
KLINISCHE PADIATRIE, 1994, 206 (02) :95-99
[3]   Capillary zone electrophoresis for the determination of light-absorbing anions in environmental samples [J].
Carou, MIT ;
Mahía, PL ;
Lorenzo, SM ;
Fernández, EF ;
Rodríguez, DP .
JOURNAL OF CHROMATOGRAPHY A, 2001, 918 (02) :411-421
[4]   BROMIDES WERE EFFECTIVE IN INTRACTABLE EPILEPSY WITH GENERALIZED TONIC-CLONIC SEIZURES AND ONSET IN EARLY-CHILDHOOD [J].
ERNST, JP ;
DOOSE, H ;
BAIER, WK .
BRAIN & DEVELOPMENT, 1988, 10 (06) :385-388
[5]  
FREIFUSS FE, 1989, ANTIEPILEPTIC DRUGS, P877
[6]   Quantification of anions and cations in environmental water samples -: Measurements with capillary electrophoresis and indirect-UV detection [J].
Hiissa, T ;
Sirén, H ;
Kotiaho, T ;
Snellman, M ;
Hautojärvi, A .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :403-411
[7]   Potentiometric flow injection determination of serum bromide in patients with epilepsy [J].
Katsu, T ;
Mori, Y ;
Matsuka, N ;
Gomita, Y .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (12) :1829-1832
[8]   ION-SELECTIVE ELECTRODE FOR SERUM BROMIDE ASSAY IN PATIENTS WITH EPILEPSY [J].
KATSU, T ;
FURUNO, K ;
YAMASHITA, S ;
KAWASAKI, H ;
GOMITA, Y ;
OHTSUKA, Y ;
OHTAHARA, S .
CLINICA CHIMICA ACTA, 1995, 234 (1-2) :157-161
[9]  
Kumae T, 1990, Nihon Eiseigaku Zasshi, V45, P627
[10]  
LI SFY, 1993, CAPILLARY ELECTROPHO, P582