X-ray microtomography scanner using time-delay integration for elimination of ring artefacts in the reconstructed image

被引:103
作者
Davis, GR
Elliott, JC
机构
[1] Dept. of Biophys. in Rel. to Dent., Queen Mary and Westfield College, University of London
关键词
microtomography; ring artefacts; CCD camera; time-delay integration;
D O I
10.1016/S0168-9002(97)00566-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Most X-ray microtomography scanners work on the same principle as third-generation medical CT scanners, that is, the same point in each projection is measured by the same detector element. This leads to ring artefacts in the reconstructed image if the X-ray sensitivities of the individual detector elements, after any analytical correction, are not all identical. We have developed an X-ray microtomography scanner which uses the time-delay integration method of imaging with a CCD detector to average the characteristics of all the detector elements in each linear projection together. This has the added advantage of allowing specimens which are larger than the detector and X-ray field to be scanned. The device also uses a novel mechanical stage to ''average out'' inhomogeneities in the X-ray field. The results show that ring artefacts in microtomographic images are eliminated using this technique.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 11 条
[1]  
BARBE DF, 1976, SOLID STATE IMAGING, P659
[2]  
DEGROOT J, 1988, P SOC PHOT INSTR ENG, V914, P246
[3]   MEASUREMENT OF DIFFUSION IN LIQUIDS WITHIN POROUS SOLIDS BY X-RAY MICRORADIOGRAPHY - DETERMINATION OF ERRORS AND OPTIMIZATION OF EXPERIMENTAL CONDITIONS [J].
DOWKER, SEP ;
ANDERSON, P ;
ELLIOTT, JC .
MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1995, 6 (02) :187-203
[4]  
ELLIOTT JC, 1994, JOM-J MIN MET MAT S, V46, P11
[5]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[6]   A TIME-DELAY INTEGRATION CHARGE-COUPLED DEVICE CAMERA FOR SLOT-SCANNED DIGITAL RADIOGRAPHY [J].
HOLDSWORTH, DW ;
GERSON, RK ;
FENSTER, A .
MEDICAL PHYSICS, 1990, 17 (05) :876-886
[7]   A HIGH-RESOLUTION XRII-BASED QUANTITATIVE VOLUME CT SCANNER [J].
HOLDSWORTH, DW ;
DRANGOVA, M ;
FENSTER, A .
MEDICAL PHYSICS, 1993, 20 (02) :449-462
[8]   X-RAY MICROTOMOGRAPHY ON BEAMLINE-X AT SSRL [J].
KINNEY, JH ;
JOHNSON, QC ;
NICHOLS, MC ;
BONSE, U ;
SAROYAN, RA ;
NUSSHARDT, R ;
PAHL, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :2471-2474
[9]   A DETECTOR FOR SCANNED PROJECTION RADIOGRAPHY [J].
SONES, RA ;
LAURO, KL ;
CATTELL, CL .
RADIOLOGY, 1990, 175 (02) :553-559
[10]   TDI CHARGE-COUPLED-DEVICES - DESIGN AND APPLICATIONS [J].
WONG, HS ;
YAO, YL ;
SCHLIG, ES .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1992, 36 (01) :83-106