Hemolysis of 40% hematocrit, Albunex(R)-supplemented human erythrocytes by pulsed ultrasound: Frequency, acoustic, pressure and pulse length dependence

被引:44
作者
Brayman, AA
Strickler, PL
Luan, H
Barned, SL
Raeman, CH
Cox, C
Miller, MW
机构
[1] UNIV ROCHESTER,DIV BIOSTAT,ROCHESTER,NY 14642
[2] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14642
关键词
pulsed ultrasound; hemolysis; Albunex(R); ultrasound bioeffects; acoustic cavitation; CAVITATION IN-VITRO; CONTRAST AGENT; DIAGNOSTIC ULTRASOUND; EXPOSURE; HEME; HEMOGLOBIN; THRESHOLDS; ALBUNEX; DAMAGE; LUNG;
D O I
10.1016/S0301-5629(97)00126-9
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The dependence of hemolysis produced by pulsed ultrasound on ultrasound frequency, acoustic pressure and pulse length was explored, Human erythrocytes (40% hematocrit; in Albunex(R)-supplemented autologous plasma) were exposed (60 s) to 20 or 200 mu s pulses of ultrasound at frequencies of 1.02, 2.24 or 3.46 MHz and at peak negative pressures [P-] ranging from 0.0 to similar to 3.0, MPa in 0.5 MPa increments, The duty factor was 0.01. At each frequency, hemolysis increased with increasing acoustic pressure and depended weakly on pulse duration, At relatively high acoustic pressures, hemolysis depended strongly on ultrasound frequency; at lower pressures, the frequency dependence was weaker, The potential clinical significance of ultrasonic hemolysis is discussed. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1237 / 1250
页数:14
相关论文
共 52 条
  • [11] Hemolysis of albunex-supplemented, 40% hematocrit human erythrocytes in vitro by 1-MHz pulsed ultrasound: Acoustic pressure and pulse length dependence
    Brayman, AA
    Azadniv, M
    Cox, C
    Miller, MW
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07) : 927 - 938
  • [12] EFFECT OF A STABILIZED MICROBUBBLE ECHO CONTRAST AGENT ON HEMOLYSIS OF HUMAN ERYTHROCYTES EXPOSED TO HIGH-INTENSITY PULSED ULTRASOUND
    BRAYMAN, AA
    AZADNIV, M
    MAKIN, IRS
    MILLER, MW
    CARSTENSEN, EL
    CHILD, SZ
    RAEMAN, CH
    MELTZER, RS
    EVERBACH, EC
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1995, 12 (01): : 13 - 21
  • [13] RENAL HANDLING OF HEMOGLOBIN .2. CATABOLISM
    BUNN, HF
    JANDL, JH
    [J]. JOURNAL OF EXPERIMENTAL MEDICINE, 1969, 129 (05) : 925 - &
  • [14] RENAL HANDLING OF HEMOGLOBIN .I. GLOMERULAR FILTRATION
    BUNN, HF
    ESHAM, WT
    BULL, RW
    [J]. JOURNAL OF EXPERIMENTAL MEDICINE, 1969, 129 (05) : 909 - &
  • [15] CARSTENSEN EL, 1992, ECHOCARDIOGR-J CARD, V6, P605
  • [16] LUNG DAMAGE FROM EXPOSURE TO PULSED ULTRASOUND
    CHILD, SZ
    HARTMAN, CL
    SCHERY, LA
    CARSTENSEN, EL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) : 817 - 825
  • [17] Hemolysis in vivo from exposure to pulsed ultrasound
    Dalecki, D
    Raeman, CH
    Child, SZ
    Cox, C
    Francis, CW
    Meltzer, RS
    Carstensen, EL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) : 307 - 313
  • [18] Drabkin DL, 1932, J BIOL CHEM, V98, P719
  • [19] DUBROW A, 1988, ACUTE RENAL FAILURE, P279
  • [20] DUCK FA, 1990, PHYSICAL PROPERTIES