Bioanalytical applications of fast capillary electrophoresis

被引:23
作者
Kennedy, RT [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
关键词
capillary electrophoresis; bioanalysis; fast separation;
D O I
10.1016/S0003-2670(99)00657-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis is unique among liquid-phase separations in its utility for fast separations. Development of technology such as optical-gating, flow-gating, and microfabrication has allowed separations on the millisecond time scale to be developed. The fast separation times place great demands on the detector systems, frequently requiring detection limits below 1 amol to be practical. The development of such fast separations has opened many new applications not previously feasible for separations-based methods. This has included real time chemical monitoring, detection of short-lived species such as protein conformers or non-covalent complexes, and rapid multi-dimensional separations. Other applications currently being developed include high-throughput assays for clinical laboratories or screening combinatorial libraries. This review covers recent developments in the instrumentation for fast CE and some of the applications. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:163 / 180
页数:18
相关论文
共 111 条
[31]   Ultrathin slab gel separations of DNA using a single capillary sample introduction system [J].
Hietpas, PB ;
Bullard, KM ;
Gutman, DA ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2292-2298
[32]   A NEW-TYPE OF PH-STABLE AND DETERGENT-STABLE COATING FOR ELIMINATION OF ELECTROENDOOSMOSIS AND ADSORPTION IN (CAPILLARY) ELECTROPHORESIS [J].
HJERTEN, S ;
KUBO, K .
ELECTROPHORESIS, 1993, 14 (5-6) :390-395
[33]   FAST, HIGH-RESOLUTION (CAPILLARY) ELECTROPHORESIS IN BUFFERS DESIGNED FOR HIGH-FIELD STRENGTHS [J].
HJERTEN, S ;
VALTCHEVA, L ;
ELENBRING, K ;
LIAO, JL .
ELECTROPHORESIS, 1995, 16 (04) :584-594
[34]   A transparent flow gating interface for the coupling of microcolumn LC with CZE in a comprehensive two-dimensional system [J].
Hooker, TF ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1997, 69 (20) :4134-4142
[35]   END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192
[36]   ON-COLUMN CONDUCTIVITY DETECTOR FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
PANG, TKJ ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2747-2749
[37]   IMPROVED END-COLUMN CONDUCTIVITY DETECTOR FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2193-2196
[38]   CAPILLARY ARRAY ELECTROPHORESIS USING LASER-EXCITED CONFOCAL FLUORESCENCE DETECTION [J].
HUANG, XHC ;
QUESADA, MA ;
MATHIES, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :967-972
[39]   Microchip structures for submillisecond electrophoresis [J].
Jacobson, SC ;
Culbertson, CT ;
Daler, JE ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (16) :3476-3480
[40]   PRECOLUMN REACTIONS WITH ELECTROPHORETIC ANALYSIS INTEGRATED ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4127-4132