Arsenic speciation by coupling capillary zone electrophoresis with mass spectrometry

被引:18
作者
Debusschere, L [1 ]
Demesmay, C [1 ]
Rocca, JL [1 ]
机构
[1] Univ Lyon 1, CNRS, UMR 5619, Sci Analyt Lab, F-69622 Villeurbanne, France
关键词
mass spectrometry; capillary zone electrophoresis; speciation; arsenic speciation;
D O I
10.1007/BF02490602
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary zone electrophoresis (CZE) has been coupled with mass spectrometry to enable the identification of mineral and organometallic compounds of arsenic in speciation studies. The electrophoretic effluent was introduced through a concentric interface into the mass spectrometer. Make-up liquid was added to enable electric contact at the outlet of the separation capillary and to assist the electronebulization process. After ionization, the ions were analyzed and quantified with an ion-trap detector. Optimization of the coupling conditions (geometry of the concentric interface, composition and flow rate of the sheath liquid, electronebulization and detection conditions) is described. The results show that the geometry of the concentric interface and the positioning of the outlet of the separation capillary have a critical effect on stability and sensitivity. Programming the electronebulization and detection conditions throughout the analysis enabled identification and quantification of the seven arsenic compounds of interest (neutral, and positively or negatively charged species) in less than 20 min at the ppm level. Limits of detection (-1), corresponding to amounts ranged from 0.5 to 3.3 mg L-1 injected ranging from 15 to 60 pg. The linear dependence of mass spectrometric response on arsenic concentration was verified for concentrations ranging from 5 to 200 mg L-1. For the two positively charged species, arsenobetaine and arsenocholine, an on-line preconcentration technique (field-amplified sample injection) enabled reduction of the detection limits by approximately one order of magnitude to 110 and 160 mu g L-1,respectively.
引用
收藏
页码:262 / 268
页数:7
相关论文
共 30 条
[1]   Large-volume stacking for quantitative analysis of anions in capillary electrophoresis .1. Large-volume stacking with polarity switching [J].
Albert, M ;
Debusschere, L ;
Demesmay, C ;
Rocca, JL .
JOURNAL OF CHROMATOGRAPHY A, 1997, 757 (1-2) :281-289
[2]   ANALYSIS OF ORGANIC AND NONORGANIC ARSENIOUS OR SELENIOUS COMPOUNDS BY CAPILLARY ELECTROPHORESIS [J].
ALBERT, M ;
DEMESMAY, C ;
ROCCA, JL .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (4-5) :426-432
[3]  
BANKS JF, 1995, J CHROMATOGR A, V712, P245
[4]   CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY [J].
CAI, JY ;
HENION, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :667-692
[5]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[6]   ARSENIC SPECIATION BY COUPLING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
DEMESMAY, C ;
OLLE, M ;
PORTHAULT, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (03) :205-210
[7]  
JAULMES P, 1971, ANN NUTR ALIMENT, V25, pB138
[8]   A CE/ESI-MS interface for stable, low-flow operation [J].
Kirby, DP ;
Thorne, JM ;
Gotzinger, WK ;
Karger, BL .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4451-4457
[9]  
LUI Q, 1995, ANAL CHEM, V67, P2949
[10]   Speciation of arsenic compounds in drinking water by capillary electrophoresis with hydrodynamically modified electroosmotic flow detected through hydride generation inductively coupled plasma mass spectrometry with a membrane gas-liquid separator [J].
Magnuson, ML ;
Creed, JT ;
Brockhoff, CA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (07) :689-695