Disposable electrochemical sensor for determination of nitroaromatic compounds by a single-run approach

被引:118
作者
Chen, Jyh-Cheng
Shih, Jiun-Le
Liu, Chi-Ho
Kuo, Mei-Yueh
Zen, Jyh-Myng [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
[2] Council Agr, Anim Hlth Res Inst, Execut Yuan, Peoples R China
关键词
D O I
10.1021/ac060002n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Environmental and security applications have generated major demands for effective field-deployable tools for detecting nitroaromatic compounds, such as chloramphenicol ( an antibiotic), parathion ( an organophosphate nerve agent), and TNT ( 2,4,6-trinitrotoluene, an explosive) in a fast, simple, sensitive, reliable, and cost-effective manner. We report here a single-run approach for such a purpose. The reduction potential of different nitroaromatic compounds was found to systematically shift with the substituent group at an electrochemically preanodized screen-printed carbon electrode. The preanodization treatment makes the peak sharp and hence provides a precise way to identify the substituent effect on nitroaromatic compounds. By using potential shifts as analytical characteristics of nitroaromatic compounds, a suitable internal standard can be chosen based on the criteria of well-separated peak potential and rarely found in the real sample of interest. Simply by measuring the ratio of peak currents between analytes of interest and internal standard, the analysis can be done in a single-run measurement. Both the matrix effect and the variation of electrode during the preparation process can be canceled out in this approach and thus allows for a high-precision analysis. Just by placing a 20-mu L drop on a single-use amperometric sensor strip incorporating a three-electrode configuration is enough for rapid and sensitive detection of nitroaromatic compounds by square-wave voltammetry. For example, the linear detection range can be up to 100 AM with a detection limit of 0.42 mu M (S/N = 3) in the detection of chloramphenicol. This approach was successfully demonstrated in real sample analysis to verify the applicability of the method. The promising performances open new possibilities for rapid determination of nitroaromatic compounds in environmental and biological samples.
引用
收藏
页码:3752 / 3757
页数:6
相关论文
共 22 条
[1]   Rapid voltammetric determination of nitroaromatic explosives at electrochemically activated carbon-fibre electrodes [J].
Agüí, L ;
Vega-Montenegro, D ;
Yáñez-Sedeño, P ;
Pingarrón, JM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) :381-387
[3]   Persistence of selected pesticides and their phenolic transformation products in natural waters using off-line liquid solid extraction followed by liquid chromatographic techniques [J].
Castillo, M ;
Domingues, R ;
Alpendurada, MF ;
Barcelo, D .
ANALYTICA CHIMICA ACTA, 1997, 353 (01) :133-142
[4]   Amperometric determination of xanthine and hypoxanthine at carbon electrodes. Effect of surface activity and the instrumental parameters on the sensitivity and the limit of detection [J].
Cavalheiro, ETG ;
Brajter-Toth, A .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :217-230
[5]   A disposable single-use electrochemical sensor for the detection of uric acid in human whole blood [J].
Chen, JC ;
Chung, HH ;
Hsu, CT ;
Tsai, DM ;
Kumar, AS ;
Zen, JM .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 110 (02) :364-369
[6]   Determination of total phenols in waters and wastewaters using flow injection with electrochemical detection; An alternative to the standard colorimetric procedure [J].
Christophersen, MJ ;
Cardwell, TJ .
ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) :39-46
[7]   DRIFT FROM A COMMERCIAL, AERIAL APPLICATION OF METHYL AND ETHYL PARATHION - AN ESTIMATION OF POTENTIAL HUMAN EXPOSURE [J].
DRAPER, WM ;
STREET, JC .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1981, 26 (04) :530-536
[8]  
EPSTEIN RL, 1994, J AOAC INT, V77, P570
[9]  
FRANCIS AC, 2000, ADV ORGANIC CHEM
[10]   Electrochemical detectors prepared by electroless deposition for microfabricated electrophoresis chips [J].
Hilmi, A ;
Luong, JHT .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4677-4682