Improvement of image quality in MR cholangiography.

被引:7
作者
Obenauer, S
Fischer, U
Heuser, M
Wilke, R
Grabbe, E
机构
[1] Klinikum Univ Gottingen, Abt Rontgendiagnost 1, D-37075 Gottingen, Germany
[2] Klinikum Univ Gottingen, Allgemeinchirurg Abt, D-37075 Gottingen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1999年 / 171卷 / 06期
关键词
magnetic resonance (MR); quality assurance; rapid imaging; contrast media; MRCP;
D O I
10.1055/s-1999-9513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To improve the image quality of magnetic resonance cholangiopancreaticography (MRCP) by modification of examination conditions. Materials and Methods: MRCP of 72 patients was performed with a 1.5 T system (Magnetom Vision, Siemens, 25 mT/m) using two breath-hold techniques, half-fourier acquisition with multislice T-2-WI HASTE in MIP technique, and single shot T-2-WI turbo-spin-echo (RARE) with different slice thicknesses. The effects of n-butylscopolamine were assessed. Furthermore, oral contrast agents [barium sulfate, Fe(ll)gluconate, Fe(ll,lll)-oxide] in various concentrations were used. The slice thickness was varied for the RARE sequence (3 - 7 cm). Results: N-butylscopolamine had no influence on image quality. Improvements could be attained by variation of the slice thickness. A significant reduction of disturbing background noise was obtained by oral application of iron gluconate, or iron oxide-containing contrast media. Similar improvements were achieved with barium sulfate. Conclusions: Variation of slice thickness allows an improvement of MRCP quality. Oral contrast media improve the image quality of MRCP. The expense of contrast media may be a determinant of choice.
引用
收藏
页码:450 / 454
页数:5
相关论文
共 30 条
[21]   Cholangiography before biliary surgery: Single-shot MR cholangiography versus intravenous cholangiography [J].
Reuther, G ;
Kiefer, B ;
Tuchmann, A .
RADIOLOGY, 1996, 198 (02) :561-566
[22]   ORAL MAGNETIC PARTICLES IN MR IMAGING OF THE ABDOMEN AND PELVIS [J].
RINCK, PA ;
SMEVIK, O ;
NILSEN, G ;
KLEPP, O ;
ONSRUD, M ;
OKSENDAL, A ;
BORSETH, A .
RADIOLOGY, 1991, 178 (03) :775-779
[23]   BILIARY OBSTRUCTION - MR CHOLANGIOGRAPHY WITH A RAPID GRADIENT-ECHO SEQUENCE (2D CE-FAST) [J].
SCHUMACHER, KA ;
WALLNER, B ;
WEIDENMAIER, W ;
FRIEDRICH, JM .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (04) :332-336
[24]  
Takahara Taro, 1995, Nippon Acta Radiologica, V55, P697
[25]   BREATH-HOLD MR CHOLANGIOPANCREATOGRAPHY WITH A LONG-ECHO-TRAIN FAST SPIN-ECHO SEQUENCE AND A SURFACE COIL IN CHRONIC-PANCREATITIS [J].
TAKEHARA, Y ;
ICHIJO, K ;
TOOYAMA, N ;
KODAIRA, N ;
YAMAMOTO, H ;
TATAMI, M ;
SAITO, M ;
WATAHIKI, H ;
TAKAHASHI, M .
RADIOLOGY, 1994, 192 (01) :73-78
[26]   ENTERIC MRI CONTRAST AGENTS - COMPARATIVE-STUDY OF 5 POTENTIAL AGENTS IN HUMANS [J].
TART, RP ;
LI, KCP ;
STORM, BL ;
ROLFES, RJ ;
ANG, PGP .
MAGNETIC RESONANCE IMAGING, 1991, 9 (04) :559-568
[27]   MR cholangio-pancreatography using on open, low magnetic field of 0.2 Tesla. Early clinical results and comparison with a higher magnetic field (1.5 Tesla) and with ERCP. [J].
Wacker, F ;
Branding, G ;
Zimmer, T ;
Faiss, S ;
Wolf, KJ .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (06) :579-584
[28]   DILATED BILIARY-TRACT - EVALUATION WITH MR CHOLANGIOGRAPHY WITH A T2-WEIGHTED CONTRAST-ENHANCED FAST SEQUENCE [J].
WALLNER, BK ;
SCHUMACHER, KA ;
WEIDENMAIER, W ;
FRIEDRICH, JM .
RADIOLOGY, 1991, 181 (03) :805-808
[29]   IMPROVED MR IMAGING OF THE UPPER ABDOMEN WITH GLUCAGON AND GAS [J].
WEINREB, JC ;
MARAVILLA, KR ;
REDMAN, HC ;
NUNNALLY, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (05) :835-838
[30]   In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: Single-shot projection technique versus multislice technique [J].
Yamashita, Y ;
Abe, Y ;
Tang, Y ;
Urata, J ;
Sumi, S ;
Takahashi, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) :1449-1454