Comparison of maximum entropy and filtered back-projection methods to reconstruct rapid-scan EPR images

被引:34
作者
Tseitlin, Mark [1 ]
Dhami, Amarjot [1 ]
Eaton, Sandra S. [1 ]
Eaton, Gareth R. [1 ]
机构
[1] Univ Denver, Dept Chem & Biochem, Denver, CO 80208 USA
关键词
EPR imaging; filtered back-projection; rapid-scan EPR; maximum entropy; LiPc; trityl-CD3;
D O I
10.1016/j.jmr.2006.09.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reconstruction of two-dimensional images by filtered back-projection (FBP) and by the maximum entropy method (MEM) was compared for spectral-spatial EPR images with differing signal-to-noise ratios. Experimental projections were recorded using direct-detected rapid scans in the presence of a series of magnetic field gradients. The slow-scan absorption lineshapes were calculated by Fourier deconvolution. A Hamming filter was used in conjunction with FBP, but not for MEM. Imperfections in real experimental data, as well as random noise, contribute to discrepancies between the reconstructed image and experimental projections, which may make it impossible to achieve the customary MEM criterion for convergence. The Cambridge MEM algorithm, with allowance for imperfections in experimental data, produced images with more linear intensity scales and more accurate linewidths for weak signals than was obtained with another MEM method. The more effective elimination of noise in baseline regions by MEM made it possible to detect weak trityl C-13 trityl hyperfine lines that could not be distinguished from noise in images reconstructed by FBP. Another advantage of MEM is that projections do not need to be equally spaced. FBP has the advantages that computational time is less, the amplitude scale is linear, and there is less noise superimposed on peaks in images. It is useful to reconstruct images by both methods and compare results. Our observations indicate that FBP works well when the number of projections is large enough that the star effect is negligible. When there is a smaller number of projections, projections are unequally spaced, and/or signal-to-noise is lower MEM is advantageous. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:157 / 168
页数:12
相关论文
共 38 条
[1]   THE TOMOGRAPHIC MAXIMUM-ENTROPY METHOD IN THE 3-D ANALYSIS OF NUCLEAR-FUEL PINS [J].
ALEXA, A ;
CRACIUNESCU, T ;
MATEESCU, G ;
DOBRIN, R .
JOURNAL OF NUCLEAR MATERIALS, 1995, 218 (02) :139-142
[2]  
[Anonymous], 1996, NUMERICAL RECIPES FO
[3]  
[Anonymous], 1991, Maximum entropy in action: a collection of expository essays
[4]   Tomographic analysis of sign-altering functions by maximum entropy method [J].
Balandin, AL .
COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2000, 39 (9-10) :15-24
[5]   Maximum entropy: A complement to Tikhonov regularization for determination of pair distance distributions by pulsed ESR [J].
Chiang, YW ;
Borbat, PP ;
Freed, JH .
JOURNAL OF MAGNETIC RESONANCE, 2005, 177 (02) :184-196
[6]   The determination of pair distance distributions by pulsed ESR using Tikhonov regularization [J].
Chiang, YW ;
Borbat, PP ;
Freed, JH .
JOURNAL OF MAGNETIC RESONANCE, 2005, 172 (02) :279-295
[7]   WHY MEM DOES NOT WORK IN MR IMAGE-RECONSTRUCTION [J].
CONSTABLE, RT ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :12-25
[8]   Progressive EPR imaging with adaptive projection acquisition [J].
Deng, YM ;
Kuppusamy, P ;
Zweier, JL .
JOURNAL OF MAGNETIC RESONANCE, 2005, 174 (02) :177-187
[9]   THE USE OF QUANTIFIED MAXIMUM-ENTROPY METHODS FOR OPTIMIZING INFORMATION FROM ELECTRON-PARAMAGNETIC-RESONANCE SPECTROSCOPY [J].
GOODMAN, BA ;
GLIDEWELL, SM ;
SKILLING, J .
FREE RADICAL RESEARCH, 1995, 22 (04) :337-347
[10]   Practical conditions and limitations for high-spatial-resolution multisite EPR oximetry [J].
Grinberg, VO ;
Smirnov, AI ;
Grinberg, OY ;
Grinberg, SA ;
O'Hara, JA ;
Swartz, HM .
APPLIED MAGNETIC RESONANCE, 2005, 28 (1-2) :69-78