Practical conditions and limitations for high-spatial-resolution multisite EPR oximetry

被引:23
作者
Grinberg, VO
Smirnov, AI
Grinberg, OY
Grinberg, SA
O'Hara, JA
Swartz, HM
机构
[1] Dartmouth Coll Sch Med, EPR Ctr Study Viable Syst, Dept Radiol, Hanover, NH 03755 USA
[2] ECentricus Consulting, Huntersville, NC USA
[3] N Carolina State Univ, Dept Chem, Raleigh, NC 27695 USA
关键词
D O I
10.1007/BF03166994
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
We have previously reported a high-spatial-resolution multisite electron paramagnetic resonance (EPR) oximetry method that is based on consecutive applications of magnetic field gradients with the same direction but different magnitudes. This method that could be called also two-gradient convolution EPR oximetry has no restrictions for the shape of solid paramagnetic materials implanted in tissue and is applicable for any particulate EPR oxygen-sensitive material with a Lorentzian line shape. To enhance the utilization of this method, a previously described algorithm was used to develop user-friendly Windows-based software. Practical conditions of application of the method were established using several different model systems. It has been shown that the spectral overlap from the adjacent sites can be neglected if the splitting between the corresponding lines exceeds the largest line width by at least a factor of 1.3. An additional requirement of the method is that the second field gradient should exceed by at least 30% the value of the first gradient. It was confirmed that the error in line width determination at L-band is proportional to the noise-to-signal ratio, and does not exceed 1% a noise-to-signal ratio of 0.1 in a typical in vivo experiment. We demonstrate that the line widths of up to 10 different sites can be determined.
引用
收藏
页码:69 / 78
页数:10
相关论文
共 8 条
[1]   High spatial resolution multi-site EPR oximetry - The use of a convolution-based fitting method [J].
Grinberg, OY ;
Smirnov, AI ;
Swartz, HM .
JOURNAL OF MAGNETIC RESONANCE, 2001, 152 (02) :247-258
[2]   Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy [J].
Hirata, H ;
Walczak, T ;
Swartz, HM .
JOURNAL OF MAGNETIC RESONANCE, 2000, 142 (01) :159-167
[3]   The effects of ketamine-xylazine anesthesia on cerebral blood flow and oxygenation observed using nuclear magnetic resonance perfusion imaging and electron paramagnetic resonance oximetry [J].
Lei, H ;
Grinberg, O ;
Nwaigwe, CI ;
Hou, HG ;
Williams, H ;
Swartz, HM ;
Dunn, JF .
BRAIN RESEARCH, 2001, 913 (02) :174-179
[4]  
NILGES M, 1990, PHYS MEDICA, V5, P195
[5]   SIMULTANEOUS MULTISITE EPR SPECTROSCOPY IN-VIVO [J].
SMIRNOV, AI ;
NORBY, SW ;
CLARKSON, RB ;
WALCZAK, T ;
SWARTZ, HM .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :213-220
[6]   ACCURACY OF OXYGEN MEASUREMENTS IN T-2 (LINE-WIDTH) EPR OXIMETRY [J].
SMIRNOVA, TI ;
SMIRNOV, AI ;
CLARKSON, RB ;
BELFORD, RL .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (06) :801-810
[7]  
Swartz HM, 1997, ADV EXP MED BIOL, V428, P663
[8]   PREPARATION AND STUDY OF A LITHIUM PHTHALOCYANINE RADICAL - OPTICAL AND MAGNETIC-PROPERTIES [J].
TUREK, P ;
ANDRE, JJ ;
GIRAUDEAU, A ;
SIMON, J .
CHEMICAL PHYSICS LETTERS, 1987, 134 (05) :471-476