Implementation of chemiluminescence detection in the multisyringe flow injection technique

被引:23
作者
Pizà, N
Miró, M
de Armas, G
Becerra, E
Estela, JM
Cerdà, V
机构
[1] Univ Illes Balears, Dept Chem, E-07071 Palma de Mallorca, Spain
[2] Univ Havana, Mat & Reagents Inst, Dept Analyt Chem, Havana, Cuba
关键词
multisyringe flow injection analysis; multicommutation; chemiluminescence; cobalt; vitamin B-12; luminol;
D O I
10.1016/S0003-2670(02)00196-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of multisyringe flow injection analysis (MSFIA) to perform liquid phase chemiluminescence (CL) analysis of trace metals using a newly developed laboratory-made luminometer is demonstrated. The noteworthy features of both the flow detector and the automated set-up are their robustness, operational simplicity and ease of construction and design. The CL reaction between 3-aminophthalhydrazide (luminol) and an oxidant species catalyzed by traces of metals in alkaline medium was chosen as a model to assess the potentialities and applicability of MSFIA with multicommutation for CL reactions. The methodology is based on merging the sample segment with plugs of an oxidant (hydrogen peroxide) and the luminol solution in alkaline medium at a total flow rate as high as 25 ml min(-1) through a four-way junction point placed as close as possible to the photosensor module. Under the optimum conditions, a linear log-log regression between light emission intensity and catalyst concentration was found over the range from 15 ng l(-1) to 5 mug l(-1) for Co(II), although all experimental data better fitted a quadratic calibration graph. An injection throughput as high as 180 h(-1) for 200 mul samples, a repeatability of 1.0% (n = 8) at the 1 ng ml(-1) level and a 3sigma detection limit of 15 ng l(-1) were the analytical features of the developed analyzer for determination of ultratrace levels of cobalt. The developed CL-MSFIA method was successfully applied to degradation studies of Vitamin B-12 (cyanocobalamin) at low acid concentrations based upon the release of cobalt from the tetrapyrrole complex. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:155 / 166
页数:12
相关论文
共 48 条
[1]   A robust multisyringe system for process flow analysis Part II.: A multi-commuted injection system applied to the photometric determination of free acidity and iron(III) in metallurgical solutions [J].
Albertús, F ;
Cladera, A ;
Cerda, V .
ANALYST, 2000, 125 (12) :2364-2371
[2]   A robust multisyringe system for process flow analysis -: Part I.: On-line dilution and single point titration of protolytes [J].
Albertús, F ;
Horstkotte, B ;
Cladera, A ;
Cerdá, V .
ANALYST, 1999, 124 (09) :1373-1381
[3]   Flow injection chemiluminescence determination of ornithine and sequential determination of ornithine and lysine by using immobilized lysine oxidase [J].
Almuaibed, AM ;
Townshend, A .
ANALYTICA CHIMICA ACTA, 1999, 388 (03) :339-343
[4]   Determination of the flavor enhancer maltol through a FIA - direct chemiluminescence procedure [J].
Alonso, MCS ;
Zamora, LL ;
Calatayud, JM .
ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) :157-163
[5]   Flow methods for the determination of polycyclic aromatic hydrocarbons using low power photomultiplier tube and charge coupled device chemiluminescence detection [J].
Andrew, KN ;
Sanders, MG ;
Forbes, S ;
Worsfold, PJ .
ANALYTICA CHIMICA ACTA, 1997, 346 (01) :113-120
[6]   Chemiluminescence-based detection:: principles and analytical applications in flowing streams and in immunoassays [J].
Baeyens, WRG ;
Schulman, SG ;
Calokerinos, AC ;
Zhao, Y ;
Campaña, AMG ;
Nakashima, K ;
De Keukeleire, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) :941-953
[7]   Determination of morphine in water immiscible process streams using sequential injection analysis coupled with acidic permanganate chemiluminescence detection [J].
Barnett, NW ;
Lenehan, CE ;
Lewis, SW ;
Tucker, DJ ;
Essery, KM .
ANALYST, 1998, 123 (04) :601-605
[8]   FLOW-INJECTION ANALYSIS OF MICROMOLAR CONCENTRATIONS OF GLUCOSE AND LACTATE IN FERMENTATION MEDIA [J].
BENTHIN, S ;
NIELSEN, J ;
VILLADSEN, J .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :145-153
[9]   COBALT DETERMINATION IN NATURAL-WATERS USING CATION-EXCHANGE LIQUID-CHROMATOGRAPHY WITH LUMINOL CHEMILUMINESCENCE DETECTION [J].
BOYLE, EA ;
HANDY, B ;
VANGEEN, A .
ANALYTICAL CHEMISTRY, 1987, 59 (11) :1499-1503
[10]   CHEMILUMINESCENCE IN DRUG ASSAY [J].
CALOKERINOS, AC ;
DEFTEREOS, NT ;
BAEYENS, WRG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (09) :1063-1071