Determination of fungicides in water using liquid phase microextraction and gas chromatography with electron capture detection

被引:75
作者
Pan, HJ [1 ]
Ho, WH [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
fungicides; water; environmental analysis; HF-LPME;
D O I
10.1016/j.aca.2004.08.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hollow fiber liquid phase microextraction (HF-LPME) and gas chromatographic-electron capture detection (GC-ECD) method for the determination of six fungicides (chlorothalonil, hexaconazole, penconazole, procymidone, tetraconazole, and vinclozolin) in 3 ml of water was described. The method used 3 mul of toluene as extraction solvent, 20 min extraction time with pH 4, stirring at 870 rpm, and no salt addition. The enrichment factors of this method were from 135 to 213. Limits of detection were in the range of 0.004-0.025 mug/l. The relative standard deviations (RSDs) at 0.1 and 5 mug/l of spiking levels were in the range 3-8%. Recoveries of six fungicides from farm water at a spiking level of 0.5 mug/l were between 90.7 and 97.6%. The method compared favorably with the traditional method in terms of the sample size, analysis time, and cost. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 25 条
[1]   Solid-phase microextraction and gas chromatography with mass spectrometric detection for the determination of pesticides in aqueous samples [J].
Aguilar, C ;
Peñalver, S ;
Pocurull, E ;
Borrull, F ;
Marcé, RM .
JOURNAL OF CHROMATOGRAPHY A, 1998, 795 (01) :105-115
[2]   MULTIRESIDUE METHOD FOR PESTICIDE DETERMINATION IN WINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CABRAS, P ;
TUBEROSO, C ;
MELIS, M ;
MARTINI, MG .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1992, 40 (05) :817-819
[3]   MICROEXTRACTION BY DEMIXING FOR THE DETERMINATION OF VOLATILE COMPOUNDS IN AQUEOUS-SOLUTIONS [J].
CACHO, J ;
FERREIRA, V ;
FERNANDEZ, P .
ANALYTICA CHIMICA ACTA, 1992, 264 (02) :311-317
[4]  
Gamón M, 2001, J AOAC INT, V84, P1209
[5]  
GILLESPIE AM, 1984, J ASSOC OFF ANA CHEM, V67, P290
[6]   Comparison of three different poly(dimethylsiloxane)-divinylbenzene fibres for the analysis of pesticide multiresidues in water samples:: structure and efficiency [J].
Gonçalves, C ;
Alpendurada, MF .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :19-26
[7]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[8]   Recovery, enrichment and selectivity in liquid-phase microextraction - Comparison with conventional liquid-liquid extraction [J].
Ho, TS ;
Pedersen-Bjergaard, S ;
Rasmussen, KE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :3-17
[9]   Automated hollow fiber-protected dynamic liquid-phase microextraction of pesticides for gas chromatography - Mass spectrometric analysis [J].
Hou, L ;
Shen, G ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) :107-116
[10]   Solvent microextraction into a single drop [J].
Jeannot, MA ;