Accelerated simulation of cone beam X-ray scatter projections

被引:113
作者
Colijn, AP
Beekman, FJ [1 ]
机构
[1] Univ Utrecht, Ctr Med, Dept Nucl Med, Image Sci Inst, NL-3584 CG Utrecht, Netherlands
[2] Univ Utrecht, Ctr Med, Rudolf Magnus Inst Neurosci, Dept Pharmacol & Anat, NL-3584 CG Utrecht, Netherlands
关键词
acceleration; Monte Carlo methods; optimization methods; scattering; X-ray tomography;
D O I
10.1109/TMI.2004.825600
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Monte Carlo (MC) methods can accurately simulate scatter in X-ray imaging. However, when low noise scatter projections have to be simulated these MC simulations tend to be very time consuming. Rapid computation of scatter estimates is essential for several applications. The aim of the work presented in this paper is to speed up the estimation of noise-free scatter projections while maintaining their accuracy. Since X-ray scatter projections are often rather smooth, an approach is chosen whereby a short MC simulation is combined with a data fitting program that is robust to projection truncation and noise. This method allows us to estimate the smooth scatter projection rapidly. The speed-up and accuracy achieved by using the fitting algorithm were validated for the projection simulation of a small animal X-ray CT system. The acceleration that can be obtained over standard MC simulations is typically two orders of magnitude, depending on the accuracy required. The proposed approach may be useful for rapid simulation of patient and animal studies and for correction of the image-degrading effects of scatter in tomography.
引用
收藏
页码:584 / 590
页数:7
相关论文
共 29 条
[1]   Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation [J].
Beekman, FJ ;
de Jong, HWAM ;
van Geloven, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) :867-877
[2]  
BOONE J, 1998, MED PHYS, V15, P721
[3]   MONTE-CARLO SIMULATION OF THE SCATTERED RADIATION DISTRIBUTION IN DIAGNOSTIC-RADIOLOGY [J].
BOONE, JM ;
SEIBERT, JA .
MEDICAL PHYSICS, 1988, 15 (05) :713-720
[4]   THE VALIDITY OF MONTE-CARLO SIMULATION IN STUDIES OF SCATTERED RADIATION IN DIAGNOSTIC-RADIOLOGY [J].
CHAN, HP ;
DOI, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (02) :109-129
[5]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[6]   Effect of scattered radiation on image noise in cone beam CT [J].
Endo, M ;
Tsunoo, T ;
Nakamori, N ;
Yoshida, K .
MEDICAL PHYSICS, 2001, 28 (04) :469-474
[7]  
FLOYD CE, 1986, J NUCL MED, V27, P1577
[8]   COMPTON SCATTER EFFECTS IN CT RECONSTRUCTIONS [J].
GLOVER, GH .
MEDICAL PHYSICS, 1982, 9 (06) :860-867
[9]   Investigation of accelerated Monte Carlo techniques for PET simulation and 3D PET scatter correction [J].
Holdsworth, CH ;
Levin, CS ;
Farquhar, TH ;
Dahlbom, M ;
Hoffman, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) :74-81
[10]   METHOD FOR ESTIMATING THE INTENSITY OF SCATTERED RADIATION USING A SCATTER GENERATION MODEL [J].
HONDA, M ;
KIKUCHI, K ;
KOMATSU, KI .
MEDICAL PHYSICS, 1991, 18 (02) :219-226