Modular separation-based fiber-optic sensors for remote in situ monitoring

被引:10
作者
Dickens, J [1 ]
Sepaniak, M [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2000年 / 2卷 / 01期
关键词
D O I
10.1039/a905881h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A modular separation-based fiber-optic sensor (SBFOS) with an integrated electronically controlled injection device is described for potential use in remote environmental monitoring. An SBFOS is a chemical monitor that integrates the separation selectivity and versatility afforded by capillary electrophoresis with the remote and high sensitivity capabilities of fiber-optic-based laser-induced fluorescence sensing. The detection module of the SBFOS accommodates all essential sensing components for dual-optical fiber, on-capillary fluorescence detection. An injection module, similar to injection platforms on micro-analysis chips, is also integrated to the SBFOS. The injection module allows for electronically controlled injection of the sample onto the separation capillary. The design and operational characteristics of the modular SBFOS are discussed in this paper. A micellar electrokinetic capillary chromatography mode of separation is employed to evaluate the potential of the sensor for in situ monitoring of neutral toxins (aflatoxins). The analytical figures of merit for the modular SBFOS include analysis times of between 5 and 10 min, separation efficiencies of approximately 10(4) theoretical plates, detection limits for aflatoxins in the mid-to-low nanomolar range, and controllable operation that results in sensor performance that is largely immune to sample matrix effects.
引用
收藏
页码:11 / 16
页数:6
相关论文
共 22 条
[1]  
ALBIN M, 1993, ANAL CHEM, V65, P489
[2]  
AUTRUP H, 1992, HDB APPLIED MYCOLOGY, V5, P213
[3]   CAPILLARY ELECTROPHORESIS OF ORGANIC AND INORGANIC CATIONS WITH INDIRECT UV DETECTION [J].
BECK, W ;
ENGELHARDT, H .
CHROMATOGRAPHIA, 1992, 33 (7-8) :313-316
[4]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[5]  
Dickens JE, 1999, J MICROCOLUMN SEP, V11, P45, DOI 10.1002/(SICI)1520-667X(1999)11:1<45::AID-MCS6>3.0.CO
[6]  
2-Z
[7]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[8]   Direct on-line injection in capillary electrophoresis [J].
Evans, CE .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :2952-2954
[9]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[10]  
GROSSMAN PD, 1992, CAPILLARY ELECTROPHO, P3