Comparisons of platinum, gold, palladium and glassy carbon as electrode materials in the design of biosensors for glutamate

被引:109
作者
O'Neill, RD
Chang, SC
Lowry, JP
McNeil, CJ
机构
[1] Univ Coll Dublin, Dept Chem, Dublin 4, Ireland
[2] Univ Newcastle Upon Tyne, Inst Nanoscale Sci & Technol, Sch Med, Sch Clin & Lab Sci, Newcastle Upon Tyne, Tyne & Wear, England
[3] Natl Univ Ireland, Dept Chem, Maynooth, Kildare, Ireland
关键词
poly( 1,2-diaminobenzene); poly(phenylenediamine); glutamate oxidase; horseradish peroxidase; Os2+-polyvinylpyridine; ascorbic acid; amperometric detection; cyclic voltammetry; hydrogen peroxide;
D O I
10.1016/j.bios.2003.12.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Four electrode materials: Pt, An, Pd and glassy carbon (GC), were studied to investigate their suitability as substrates in the development of two different classes of glutamate biosensor. Glutamate oxidase cross-linked onto poly(o-phenylenediamine) was chosen as the type I biosensor (PPD/GluOx), incorporating PPD as the permselective element to detect H2O2 directly on the electrode surface at relatively high applied potentials. GluOx and horseradish peroxidase/redox polymer modified electrodes (Os2+ PVP/HRP/GluOx) that relied on enzyme-catalysed H2O2, detection at lower applied potentials were used as type 2 biosensors. The voltammetric and amperometric responses to the enzyme signal transduction molecule, H2O2 and the archetypal interference species in biological applications, ascorbic acid, were determined on the bare and PPD/GluOx-modified surfaces. The amperometric responses of these electrodes were stable over several days of continuous recording in phosphate buffered saline (pH 7.4). The sensitivity of the type I biosensors to H2O2 and glutamate showed parallel trends with low limits of detection and good linearity at low concentrations: Pt > An similar to Pd much greater than GC. Type 2 biosensors out-performed the type I design for all electrode substrates, except Pt. However, the presence of the permselective PPD membrane in the type I biosensors, not feasible in the type 2 design, suggests that Pt/PPD/GluOx might have the best all-round characteristics for glutamate detection in biological media containing interference species such as ascorbic acid. Other points affecting a final choice of substrate should include factors such as mass production issues. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1521 / 1528
页数:8
相关论文
共 55 条
[31]  
Mikeladze E, 2002, ELECTROANAL, V14, P1052, DOI 10.1002/1521-4109(200208)14:15/16<1052::AID-ELAN1052>3.0.CO
[32]  
2-0
[33]  
Miscoria SA, 2002, ELECTROANAL, V14, P981, DOI 10.1002/1521-4109(200208)14:14<981::AID-ELAN981>3.0.CO
[34]  
2-1
[35]   Electrochemical metallisation of carbon electrodes [J].
O'Connell, PJ ;
O'Sullivan, CK ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 1998, 373 (2-3) :261-270
[36]   Monitoring brain chemistry in vivo: Voltammetric techniques, sensors, and behavioral applications [J].
O'Neill, RD ;
Lowry, JP ;
Mas, M .
CRITICAL REVIEWS IN NEUROBIOLOGY, 1998, 12 (1-2) :69-127
[37]   THE STEEPNESS OF VOLTAMMETRIC WAVES [J].
OLDHAM, KB .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 184 (02) :257-267
[38]  
ONEILL RD, 2000, ENCY ANAL CHEM, P676
[39]  
ONEILL RD, 1995, VOLTAMMETRIC METHODS, P921
[40]   THE OXIDATION OF ASCORBIC-ACID AT CARBON PASTE ELECTRODES - MODIFIED RESPONSE FOLLOWING CONTACT WITH SURFACTANT, LIPID AND BRAIN-TISSUE [J].
ORMONDE, DE ;
ONEILL, RD .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 279 (1-2) :109-121