On-line solid phase extraction coupled to capillary LC-ESI-MS for determination of fluoxetine in human blood plasma

被引:34
作者
Saber, Amr L. [1 ]
机构
[1] Zagazig Univ, Fac Sci, Dept Chem, Zagazig, Egypt
关键词
Capillary liquid chromatography; Column switching; Fluoxetin hydrochloride; Mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; FLUORESCENCE DETECTION; MASS-SPECTROMETRY; NORFLUOXETINE ENANTIOMERS; GAS-CHROMATOGRAPHY; MAIN METABOLITES; HPLC; ULTRAVIOLET; CITALOPRAM; ANTIDEPRESSANTS;
D O I
10.1016/j.talanta.2008.11.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An instrumental setup including on-line solid phased extraction coupled to capillary liquid chromatography-electrospray ionization-mass spectrometry (SPE-capLC-ESI-MS) has been constructed to improve the sensitivity for quantification of fluoxetine hydrochloride in human plasma. Prior to injection, 0.5 mL of plasma spiked with metronidazole (internal standard) was mixed with ammonium formate buffer for effective chloroform liquid-liquid extraction. The method was validated in the range 5-60 ng mL(-1) fluoxetine, yielding a correlation coefficient of 0.999 (r(2)). The within-assay and between-assay precisions were between (8.5 and 11%) and (6.6 and 7.5%), respectively. The method was used to determine the amount of fluoxetine in a healthy male 14 h after an intake of one capsule of the antidepressant and anorectic Flutin (R), which contains 20 mg fluoxetine per each capsule. Fluoxetine was detected, and the concentration was calculated to 9.0 ng mL(-1) plasma. In the preliminary experiments, conventional LC-UV instrumentation was employed. However, it was found that employing a capillary column with an inner diameter of (0.3 mm I.D. x 50 mm, Zorbax C-18) increased the sensitivity by a factor of similar to 100, when injecting the same mass of analyte. Incorporating an easily automated C18 reversed phase column switching system with SPE(1.0 mm I.D. x 5.0 mm, 5 mu m) made it possible to inject up to 100 mu L of solution, and the total analysis time was 5.5 min. Published by Elsevier B.V.
引用
收藏
页码:295 / 299
页数:5
相关论文
共 31 条
[1]   Determination of fluoxetine and norfluoxetine in plasma by a modified high performance reversed phase liquid chromatographic method with fluorescence detection [J].
Atta-Politou, J ;
Fraskou, P ;
Koupparis, M .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (18) :2957-2972
[2]   FLUOXETINE - A REVIEW OF ITS PHARMACODYNAMIC AND PHARMACOKINETIC PROPERTIES, AND THERAPEUTIC EFFICACY IN DEPRESSIVE-ILLNESS [J].
BENFIELD, P ;
HEEL, RC ;
LEWIS, SP .
DRUGS, 1986, 32 (06) :481-508
[3]   Rapid liquid chromatography-tandem mass spectrometry method for the determination of a broad mixture of pharmaceuticals in surface water [J].
Conley, Justin M. ;
Symes, Steven J. ;
Kindelberger, Scott A. ;
Richards, Sean A. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1185 (02) :206-215
[4]   LC-MS/MS method for the determination of nine antidepressants and some of their main metabolites in oral fluid and plasma -: Study of correlation between venlafaxine concentrations in both matrices [J].
de Castro, A. ;
Concheiro, M. ;
Quintela, O. ;
Cruz, A. ;
Lopez-Rivadulla, M. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (01) :183-193
[5]  
Feighner J P., 1991, Selective serotonin re-uptake inhibitors: the clinical use o f Citalopram, Fluoxetine, Fluvoxamine, Paroxetine, and Sertraline
[6]   Determination of fluoxetine in plasma by gas chromatography-mass spectrometry using stir bar sorptive extraction [J].
Fernandes, Christian ;
Van Hoeck, Els ;
Sandra, Pat ;
Lancas, Fernando M. .
ANALYTICA CHIMICA ACTA, 2008, 614 (02) :201-207
[7]   Solid-phase microextraction-liquid chromatography (SPME-LC) determination of fluoxetine and norfluoxetine in plasma using a heated liquid flow through interface [J].
Fernandes, Christian ;
Santos-Neto, Alvaro Jose ;
Rodrigues, Jose Carlos ;
Alves, Claudete ;
Lancas, Fernando Mauro .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 847 (02) :217-223
[8]   Direct analysis of fluoxetine and norfluoxetine in plasma by gas chromatography with nitrogen-phosphorus detection [J].
Fontanille, P ;
Jourdil, N ;
Villier, C ;
Bessard, G .
JOURNAL OF CHROMATOGRAPHY B, 1997, 692 (02) :337-343
[9]  
GONCALVES BJ, 2008, J CHROMATOGR B, V862, P181
[10]   DETERMINATION OF FLUOXETINE AND NORFLUOXETINE IN SERUM BY LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
GUPTA, RN ;
STEINER, M .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (19) :3785-3797