Methods for measuring fluoroscopic skin dose

被引:71
作者
Balter, Stephen
机构
[1] Columbia Univ, Med Ctr, Dept Med, New York, NY 10032 USA
[2] Columbia Univ, Med Ctr, Dept Radiol, New York, NY 10032 USA
关键词
fluoroscopic skin dose; interventional radiography;
D O I
10.1007/s00247-006-0193-3
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
This paper briefly reviews available technologies for measuring or estimating patient skin dose in the interventional fluoroscopic environment.
引用
收藏
页码:136 / 140
页数:5
相关论文
共 10 条
  • [1] Radiation doses in interventional radiology procedures: The RAD-IR study Part III: Dosimetric performance of the interventional fluoroscopy units
    Balter, S
    Schueler, BA
    Miller, DL
    Cole, PE
    Lu, HT
    Berenstein, A
    Albert, R
    Georgia, JD
    Noonan, PT
    Russell, EJ
    Malisch, TW
    Vogelzang, RL
    Geisinger, M
    Cardella, JF
    St George, J
    Miller, GL
    Anderson, J
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (09) : 919 - 926
  • [2] Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures
    Cusma, JT
    Bell, MR
    Wondrow, MA
    Taubel, JP
    Holmes, DR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (02) : 427 - 435
  • [3] Real-time quantification and display of skin radiation during coronary angiography and intervention
    den Boer, A
    de Feijter, PJ
    Serruys, PW
    Roelandt, JRTC
    [J]. CIRCULATION, 2001, 104 (15) : 1779 - 1784
  • [4] Evaluation of an on-line patient exposure meter in neuroradiology
    Gkanatsios, NA
    Huda, W
    Peters, KR
    Freeman, JA
    [J]. RADIOLOGY, 1997, 203 (03) : 837 - 842
  • [5] *INT EL COMM, 2000, 60601 IEC 2
  • [6] Entrance skin dose estimates derived from dose-area product measurements in interventional radiological procedures
    McParland, BJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (852) : 1288 - 1295
  • [7] Radiation doses in interventional radiology procedures: The RAD-IR Study - Part I: Overall measures of dose
    Miller, DL
    Balter, S
    Cole, PE
    Lu, HT
    Schueler, BA
    Geisinger, M
    Berenstein, A
    Albert, R
    Georgia, JD
    Noonan, PT
    Cardella, JF
    George, JS
    Russell, EJ
    Malisch, TW
    Vogelzang, RL
    Miller, GL
    Anderson, J
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (06) : 711 - 727
  • [8] Miller DL, 2003, J VASC INTERV RADIOL, V14, P977
  • [9] Correlation of patient skin doses in cardiac interventional radiology with dose-area product
    van de Putte, S
    Verhaegen, F
    Taeymans, Y
    Thierens, H
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (869) : 504 - 513
  • [10] Skin dose and dose-area product values for interventional cardiology procedures
    Vano, E
    Gonzalez, L
    Ten, JI
    Fernandez, JM
    Guibelalde, E
    Macaya, C
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (877) : 48 - 55