Evaluation of a compact bench top immunoassay analyzer for automatic and near continuous monitoring of a sample for environmental contaminants

被引:15
作者
Glass, TR
Saiki, H
Joh, T
Taemi, Y
Ohmura, N
Lackie, SJ
机构
[1] Cent Res Inst Elect Power Ind, Dept Biosci, Abiko, Chiba 2701194, Japan
[2] Sapidyne Instruments Inc, Boise, ID 83706 USA
关键词
environmental; automated immunoassay; biosensor; coplanar PCB; dioxin; estradiol;
D O I
10.1016/j.bios.2004.02.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A compact bench top immunoassay analyzer is evaluated and shown to possess sufficient automation to allow continuous unattended sampling and measuring while still achieving the theoretical (antibody affinity based) detection limit for analyte. The system is comprised of antigen coated particles in a disposable flow cell held at the focus of a filter fluorometer. Capture of fluorescently labeled antibody from the flow stream is inhibited by analyte in the sample, allowing analyte concentrations to be determined from the fluorescent intensity. The disposable cell was designed to allow easy end user changing of test specificity, e.g. for selection of any member of a panel of environmental contaminants. Standard curves are shown for six analytes of environmental interest, dioxin F114 (2,3,4,7,8-PeCDF), the pesticide Fenitrothion, three coplanar PCBs, including the most toxic, PCB 126, and estradiol. In each case the curves are constructed using antibody concentrations at or below the K-d of the antibody, assuring that the sensitivity shown is limited by the antibody itself rather than the analyzer. The dynamic range for the six analytes investigated ranged from a low of 5 to 340 pM for fenitrothion to a high of 0.8 to 59 nM for dioxin F114, and is correlated to the antibody K-d in every case. Data is also shown for 17 consecutive samples, including both high and low values, measured completely automatically over a period of hours. With further development and characterization, the bench top analyzer is expected to fill an important niche in environmental testing. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:397 / 403
页数:7
相关论文
共 10 条
[1]   IMMUNOASSAY SCREENS FOR ALACHLOR IN RURAL WELLS - FALSE POSITIVES AND AN ALACHLOR SOIL METABOLITE [J].
BAKER, DB ;
BUSHWAY, RJ ;
ADAMS, SA ;
MACOMBER, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (03) :562-564
[2]   Analysis and occurrence of estrogenic hormones and their glucuronides in surface water and waste water in The Netherlands [J].
Belfroid, AC ;
Van der Horst, A ;
Vethaak, AD ;
Schäfer, AJ ;
Rijs, GBJ ;
Wegener, J ;
Cofino, WP .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 225 (1-2) :101-108
[3]   Comparison of two fluorescence immunoassay methods for the detection of endocrine disrupting chemicals in water [J].
Coille, I ;
Reder, S ;
Bucher, S ;
Gauglitz, G .
BIOMOLECULAR ENGINEERING, 2002, 18 (06) :273-280
[4]  
GLASS TR, 2003, ANAL CHEM 1218
[5]  
GOSLING JP, 1990, CLIN CHEM, V36, P1408
[6]   Development of the piezoelectric biosensor for acetochlor detection [J].
Lebedev, MY ;
Eremin, SA ;
Skládal, P .
ANALYTICAL LETTERS, 2003, 36 (11) :2443-2457
[7]   Combinational use of antibody affinities in an immunoassay for extension of dynamic range and detection of multiple analytes [J].
Ohmura, N ;
Tsukidate, Y ;
Shinozaki, H ;
Lackie, SJ ;
Saiki, H .
ANALYTICAL CHEMISTRY, 2003, 75 (01) :104-110
[8]   An immunoassay for small analytes with theoretical detection limits [J].
Ohmura, N ;
Lackie, SJ ;
Saiki, H .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3392-3399
[9]   Detection of hormone mimics in water using a miniturised SPR sensor [J].
Sesay, AM ;
Cullen, DC .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2001, 70 (1-2) :83-92
[10]   Immunochromatographic techniques - a critical review [J].
Weller, MG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7) :635-645