Microfabricated ISEs:: critical comparison of inherently conducting polymer and hydrogel based inner contacts

被引:112
作者
Gyurcsányi, RE
Rangisetty, N
Clifton, S
Pendley, BD
Lindner, E
机构
[1] Univ Memphis, Herff Coll Engn, Hlth Sci Ctr, Dept Biomed Engn, Memphis, TN 38152 USA
[2] Univ Memphis, Joint Grad Program Biomed Engn, Memphis, TN 38152 USA
[3] Tech Univ Budapest, Inst Gen & Analyt Chem, H-1111 Budapest, Hungary
[4] Rhodes Coll, Memphis, TN 38112 USA
基金
美国国家科学基金会; 匈牙利科学研究基金会;
关键词
planar potassium selective electrode; solid inner contact; conductive polymer; PPy/FeCN; hydrogel;
D O I
10.1016/j.talanta.2003.12.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rigorous side by side comparison of miniature planar potassium-selective electrodes with hydrogel and potassium hexacyanoferrate(II)/(II) doped polypyrrole (PPy/FeCN) based inner contacts is presented. The planar electrodes were manufactured by screen printing as four- and five-site arrays on ceramic substrates. These electrode arrays were incorporated into a flow-through cell, which could accommodate nine electrode sites. Two identical flow cells were connected in series and the effect of the inner contacts on the analytical performance of the respective electrodes has been critically evaluated. The time necessary to reach steady state conditions has been determined and the effect of experimental parameters (temperature, ambient light intensity, CO2, and O-2 concentration of the sample) on the potential stability of the electrodes was analyzed. At controlled temperature, the drift of the planar potassium electrodes with hydrogel and PPy/FeCN solid contact were 0.11 +/- 0.02 mV h(-1) and 0.03 +/- 0.007 mV h(-1), respectively. The experimental data proved that there is no aqueous film formation between the PPy/FeCN film and the potassium-selective solvent polymeric membrane. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 99
页数:11
相关论文
共 47 条
[1]   Ion sensors: current limits and new trends [J].
Bakker, E ;
Diamond, D ;
Lewenstam, A ;
Pretsch, E .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :11-18
[2]   The new wave of ion-selective electrodes. [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :420A-426A
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]  
BERGQUIST C, 2000, Patent No. 6123820
[7]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[8]   SINGLE PIECE ALL-SOLID-STATE ION-SELECTIVE ELECTRODE [J].
BOBACKA, J ;
LINDFORS, T ;
MCCARRICK, M ;
IVASKA, A ;
LEWENSTAM, A .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3819-3823
[9]   ALL-SOLID-STATE POLY(VINYL CHLORIDE) MEMBRANE ION-SELECTIVE ELECTRODES WITH POLY(3-OCTYLTHIOPHENE) SOLID INTERNAL CONTACT [J].
BOBACKA, J ;
MCCARRICK, M ;
LEWENSTAM, A ;
IVASKA, A .
ANALYST, 1994, 119 (09) :1985-1991
[10]  
BUCK RP, 1976, ANAL CHEM, V48, pR23