Chromatographic properties of reversed-phase stationary phases under pressure- and electro-driven conditions

被引:16
作者
Jiskra, J
Cramers, CA
Byelik, M
Claessens, HA
机构
[1] Eindhoven Univ Technol, Dept Instrument Anal, NL-5600 MB Eindhoven, Netherlands
[2] Ukrainian Acad Sci, Inst Bioorgan Chem & Petrochem, UA-253660 Kiev 94, Ukraine
关键词
stationary phases; LC; electrochromatography; hydrophobicity; silanols; hydrophobic selectivity; reversed-phase materials;
D O I
10.1016/S0021-9673(99)00933-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Seven different reversed-phase (RP) stationary phases were examined under high-performance liquid chromatographic (pressure-driven, HPLC), and capillary electrochromatographic (electro-driven, CEC) conditions. Characterization of the stationary phases was performed following well-established test procedures providing a number of distinct column descriptors: hydrophobicity, hydrophobic selectivity and silanol activity. These parameters were used to describe the behavior of the RP-columns under both HPLC and CEC conditions. It is shown that chromatographic characteristics of porous RP-phases greatly depend on the mode of operation. By contrast, column descriptors of a non-porous viz. solid RP-phase material hardly differed for HPLC and CEC conditions. (C) 1999 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:121 / 135
页数:15
相关论文
共 51 条
[1]   Method development in pharmaceutical analysis employing capillary electrochromatography [J].
Angus, PDA ;
Victorino, E ;
Payne, KM ;
Demarest, CW ;
Catalano, T ;
Stobaugh, JF .
ELECTROPHORESIS, 1998, 19 (12) :2073-2082
[2]   CHARACTERIZATION OF SILICA-BASED REVERSED-PHASE COLUMNS WITH RESPECT TO RETENTION SELECTIVITY - SOLVOPHOBIC EFFECTS [J].
ANTLE, PE ;
GOLDBERG, AP ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (01) :1-32
[3]   PRESSURIZED GRADIENT ELECTRO-HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BEHNKE, B ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :93-98
[4]   GENERATION OF SPIT-FLOW MICRO-GRADIENTS FOR CAPILLARY HPLC [J].
BERLONI, A ;
CAPPIELLO, A ;
FAMIGLINI, G ;
PALMA, P .
CHROMATOGRAPHIA, 1994, 39 (5-6) :279-284
[5]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[6]  
CHERVET JP, 1989, HRC-J HIGH RES CHROM, V12, P278
[7]   Influence of the electrical double-layer on electroosmotic flow in capillary electrochromatography [J].
Cikalo, MG ;
Bartle, KD ;
Myers, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (01) :35-51
[8]   Effect of buffers on silica-based column stability in reversed-phase high-performance liquid chromatography [J].
Claessens, HA ;
vanStraten, MA ;
Kirkland, JJ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :259-270
[9]  
CLAESSENS HA, 1993, LC GC EUR, V6, P692
[10]  
Dittmann MM, 1995, LC GC-MAG SEP SCI, V13, P800